AC Power Receptacle
The 3300 PowerDsine 24PT In-Line Power Unit automatically adjusts its power setting to any
supply voltage in the range 100–240Vac.
PowerDsine 24PT In-Line Power Unit Dimensions
Height
Width
Depth
Weight
PowerDsine 24PT In-Line Power Unit Environment
Mode
Temperature
Operating
0 to 40°C (32 to 104°F)
Storage
-20 to 70°C (-4 to 158°F)
PowerDsine 24PT In-Line Power Unit Power
The PowerDsine 24PT In-Line Power Unit is designed to power devices that are Power over
LAN Enabled and are IEEE 802.3af compliant. Devices that are not compliant may require an
external power adapter to be powered.
Input Voltage
Input Current (90/264VAC)
Maximum Power Input at full load
Output Power, per Port (Note)
Nominal Output Voltage, per Port
Note: Maximum power output is 200W for the 24 port hub. See User Manual for power allocation
details.
PowerDsine 24PT In-Line Power Unit Interfaces
The PowerDsine 24Pt In-Line Power Unit is a 24 Ethernet channel power feeding device. The
unit is designed for use with a 10/100 Base-Tx standard Ethernet network over a standard
TIA/EIA-568 Category 5, 6 or 6e cabling plant. The DC operating power for the data terminal
units is fed through the unused pairs (7/8 and 4/5).
Physical Dimensions
1.75 in. (4.4 cm) (1 U)
17.0 in. (43.2 cm)
19.0 in. (48.3 cm) with 19" rack mount brackets
11.9 in. (30.2 cm)
8.8 lb (4.0 kg)
Storage and Operating Environment
Power Supply PD-PH-6024/AC/48
Output Power
Release 3.3
Humidity
10 to 90% (no condensing)
10 to 90% (no condensing)
90 to 264 VAC (47-63 Hz)
4 / 2 Amps RMS
270 Watts
16.8 Watts
44 – 57VDC