Mitel 3300 ICP Hardware User's Manual page 91

Integrated communications platform
Table of Contents

Advertisement

Note: The ONS CLASS/CLIP line card is available in NA and the UK only.
Feature
NA
MC320 Card
BD, BE for
Variants
ONS line
card; EA for
ONS
CLASS/CLIP
line card
PCM Coding
µ-law
External Loop
600 ohms
Resistance
(see Note 1)
External Wire
400 ohms
Resistance
(see Note 2)
Power
BD: 9.09 W
Consumption
BE: 9.82 W
Message
Yes
Waiting (see
Note 4)
Calibrated
No
Flash
Nominal
80 Vrms @ 20
Ringing
Hz
Voltage
Nominal Trip
-27 Vdc
Battery
Silent Interval
External Loop
3800 m
Length:
(12350 ft.)
22 AWG (23
1500 m
IWG)
(4875 ft.)
26 AWG (27
IWG
* International = Caribbean, Cuba, Europe, Middle East and Africa
Notes:
1. Stations whose line loop resistances range between 400 and 1600 ohms must terminate on an
OPS line card.
2. External wire resistance measurements are based on the assumption that a 200 ohm set was
used.
3. The German variant also provides impedance matching, fixed and variable gains, as well as Tip
and Ring protection, with selectable fuse or EMI choke option.
4. The message waiting circuit for the ONS CLASS/CLIP line card has a voltage below 120v on the
ring lead.
Operation
Incoming analog calls are converted to digital (PCM) signals by one of 16 line circuit modules
on the ONS line card. Calls are switched by the Main Controller and the two parties are
ONS Line Card Variant Specifications
Germany
CH
CG
A-law
A-law
850 ohms
600 ohms
@ 23mA
650 ohms
400 ohms
9.64 W
9.82 W
Yes
Yes
Yes
Yes
65 Vrms @ 25
80 Vrms @ 25
Hz
Hz
-30 Vdc
-27 Vdc
3700 m
(12025 ft.)
Release 3.3
China
UK
CD for ONS
line card; EB
for ONS
CLASS/CLIP
line card
A-law
600 ohms
400 ohms
9.82 W
Yes
Yes
80 Vrms @ 25
Hz
-27 Vdc
3700 m
(12025 ft.)
Specifications
Int'l*
CE
A-law
600 ohms
400 ohms
9.82 W
Yes
Yes
80 Vrms @ 25
Hz
-27 Vdc
3700 m
(12025 ft.)