Mitel 3300 ICP Hardware User's Manual page 218

Integrated communications platform
Table of Contents

Advertisement

3300 ICP Hardware User Guide
To remove an MMC Module:
1. Remove the cover.
2. Remove the screws ad lock washers from the module.
3. Pull up on the module to remove it.
4. Replace the cover.
To install DSP Modules:
1. Remove the cover.
2. Line up the connectors module and firmly seat onto the board.
3. Secure the module onto the board using the screws and lock washers provided.
4. Replace the cover.
Hard Drive
CAUTION: To prevent ESD damage while handling modules on any unit, always attach
the wrist strap from the cabinet being serviced, and immediately place any item removed
from a cabinet into an anti-static bag.
To replace the hard drive:
1. Turn off the power to the unit.
2. Disconnect all cables.
3. Place the 3300 Controller on the work area with the bottom of the unit facing up.
4. To remove the hard drive, remove the 6 smaller, border screws (the four larger screws
secure the hard drive to the backing plate).
5. Replace the hard drive.
6. Return power to the unit but do not connect to the network.
7. Reset the IP Address of the RTC, through the RS232 port, to the default 192.168.1.2.
8. Set the IP Address of the source PC to match the RTC IP scheme.
9. Connect the PC NIC to the 3300 ICP.
10. Configure the FTP server for the install process.
11. From the software CD-ROM, select INSTALL.
12. Reboot the system.
13. Login to the System Administration Tool.
14. Restore a backup.
15. Reset the RTC IP Address to the customer setting.
16. Connect to the network.
17. Reset the system.
210
Release 3.3

Advertisement

Table of Contents
loading

Table of Contents