3300 ICP Hardware User Guide
3300 R2 NSU DIP Switch Settings
DIP Switch
1
2
3
4
5
6
BNC Adapter
Required
No
No
Yes
Yes
Note: Site dependent - normally Tx is grounded and Rx is not grounded, but that depends on which
remote connection is grounded.
Mitel Networks™ 3300 BRI NSU Components
Front panel
•
RS-232 serial port (DB9 connector) for installation, configuration, and maintenance
•
BRI Circuit LEDs
•
CEPT link Status LED
•
Power LED
•
Reset pin.
Rear panel
•
Ethernet port (RJ-45 connector) for future use
•
E1 port to connect to an NSU that is running E1 DPNSS
•
E1 port DIP switches
•
BRI connector (25-pair male D-type)
60
MF-R2 Port DIP Switch Settings
Use
Tx Ground
Rx Ground
Impedance selector #1
Impedance selector #2
Impedance selector #3
LT/NT selector
E1/MF-R2 Mode/Connector DIP Switch Setting
Imped
LT/NT
ance
Mode
Tx Gnd
120
NT
120
LT
75
NT
75
LT
Default Setting
Notes
Up
Tx shield ground when down
Up
Rx shield ground when down
Up
120 ohm
Up
100 ohm
Up
75 ohm
Up
Up for NT, down for LT
1
2
Rx Gnd
Up
Up
Up
Up
Note
Note
Note
Note
Release 3.3
3
4
5
120
100
75
ohm
ohm
ohm
Down
Up
Up
Down
Up
Up
Up
Up
Down
Up
Up
Down
6
LT/NT
Up
Down
Up
Down