Chapter 4 Configuration
4.2
This section explains how to operate the unit.
Setting Device-Level Parameters
This section includes procedures for setting the configuring fault propagation
options.
Configuring Fault Propagation
When the Network > User Fault Propagation feature is enabled, the LAN ports are
deactivated when the PCS uplink goes down. They will come up again once the
PCS port is resynchronized.
To configure the fault propagation:
1. Select Main Menu>Configuration>System.
2. Select Fault Propagation.
3. Select Network>User Fault Propagation and toggle between Enable and
4. Press <S> to save the changes.
Main Menu > Configuration > System > Fault Propagation
1. Network - >
S - Save
ESC-Previous menu; !-Main menu; &-Exit
Configuring Date and Time
The Date and Time screen is used to configure the NTP client parameters.
The NTP client is used as a means to receive the date and time from the network.
When the NTP server is properly configured and accessible, the device displays
the real date and time as was received from the NTP server, instead of the
system uptime, which is the default state.
4-8
Configuring for Operation
Configuring for Operation
The Configuration System screen appears (see
The Fault Propagation screen appears (see
Disable.
User Fault Propagation
Figure 4-12. Fault Propagation Screen
Installation and Operation Manual
Figure 4-2
Figure 4-12
ASMi-54
(Disable)
).
).
ASMi-54 Ver. 1.0