G.shdsl.bis modem
Table of Contents

Advertisement

Chapter 4 Configuration
Configuring the SHDSL Ports
This section includes procedures for configuring the SHDSL PCS ports, configuring
the SHDSL PME ports, and setting the clock source.
Configuring the SHDSL PCS Ports
To configure SHDSL PCS ports:
1. Select Main Menu > Configuration > Physical Layer.
2. Select SHDSL.
Main Menu > Configuration > Physical Layer > SHDSL
PCS (Physical Coding Sublayer)
Administrative Status
Power Backoff
1. Clock Source
2. PME Configuration
>
F-Forward
ESC-Previous menu; !-Main menu; &-Exit
Parameter
Possible Values
PCS (Physical
1
Coding
Sublayer)
Up
Administrative
Status
Down
Power Backoff
Disable
Clock Source
Internal: STU-C
RX Clock: STU-R
4-12
Configuring for Operation
The Physical Layer screen appears (see
The SHDSL PCS Port Configuration screen appears (see
parameters are described in
Figure 4-16. SHDSL PCS Port Configuration Screen
Table 4-3. SHDSL PCS Port Configuration Parameters
Remarks
Index of the SHDSL PCS.
Default: 1
Administrative status of the SHDSL PCS.
Default: Up
The power backoff mode.
Default: Disable
Note: This parameter is Read Only and cannot be configured.
The source clock determines SHDSL mode (STU-C or STU-R). If source
clock is receive (RX), source port is the first connected SHDSL line.
Default: RX Clock: STU-R
Installation and Operation Manual
Figure 4-14
Table 4-3
.
ASMi-54
(1)
(Up)
(Disable)
(RX Clock: STU-R)
>
).
Figure 4-16
). The
ASMi-54 Ver. 1.0