Configuring Physical-Level Port Parameters - Access RAD ASMi-54 Installation And Operation Manual

G.shdsl.bis modem
Table of Contents

Advertisement

Installation and Operation Manual
To configure the NTP client parameters:
1. Select Main Menu>Configuration>System.
2. Select Date and Time.
3. Press <S> to save the changes.
Main Menu > Configuration > System > Date and Time
1
2
3
4
5
ESC-Previous menu; !-Main menu; &-Exit
Parameter
Possible Values
NTP Mode
Unicast Client
Disable
-12 ... 12
GMT
NTP Server IP
xxx.xxx.xxx.xxx
Address
NTP Update
0 (disable)
Interval (sec)
1 ... 4294967295
Send Initiated
NTP Request

Configuring Physical-Level Port Parameters

ASMi-54 has one or four Fast Ethernet interfaces and up to four SHDSL interface.
The Fast Ethernet and SHDSL configuration menus are accessed from the Physical
Layer menu.
ASMi-54 Ver. 1.0
The Configuration System screen appears (see
The Date and Time screen appears (see
Table 4-1
described in
Date
Time
NTP Mode
GMT
NTP Server IP Address
NTP Update Interval (sec)
Send Initiated NTP Request
Figure 4-13. Date and Time Screen
Table 4-1. Date and Time Configuration Parameters
Remarks
NTP request is sent to a specific IP address
Default: Disable
Offset from Greenwich Mean Time
Default: 0
Default: 0.0.0.0
Time (in seconds) between NTP requests
Default: 0 (disable)
Each time this is pressed, an NTP request is sent regardless of the
NTP update interval.
Figure 4-13
.
ASMi-54
...(01-10-1949)
...(00:00:01)
>
>
...(172.17.163.93)
...(5)
Configuring for Operation
Chapter 4 Configuration
Figure 4-2
).
). The parameters are
(Unicast Client)
(0)
4-9