Access RAD ASMi-54 Installation And Operation Manual page 33

G.shdsl.bis modem
Table of Contents

Advertisement

Chapter 2
Installation and Setup
This chapter includes the following topics:
2.1
An ASMi-54 unit is delivered completely assembled, and is factory set for basic
operation. It is designed for installation as a desktop unit or for mounting in a
19-inch rack. For rack installation instructions, refer to the
19-inch Racks
After installing the unit, use an ASCII terminal connected to the CONTROL port to
perform any configuration necessary. The configuration procedures are described
in
If problems are encountered, refer to
No internal settings, adjustment, maintenance and repairs should be performed
by either the operator or the user. Such activities must be performed only by
skilled personnel who are aware of the hazards involved.
Warning
Always observe standard safety precautions during installation, operation, and
maintenance of this product.
2.2
AC-powered ASMi-54 units should be installed within 1.5m (5 feet) of an easily
accessible grounded AC outlet capable of furnishing the required supply voltage,
in the range of 100 to 240 VAC, 50 or 60 Hz.
DC-powered ASMi-54 units require a -48 VDC power source, which must be
adequately isolated from the main supply.
Allow at least 90 cm (36 in) of frontal clearance for operator access. For
continuous product operation allow at least 10 cm of frontal clearance and at
least 15 cm at rear of the unit, for cable connections and ventilation. For proper
ventilation, keep at least 2.5 cm clearance from the sides and top of the product.
ASMi-54 Ver. 1.0
Site requirements and prerequisites
Package contents
Equipment needed
Installation and setup.
Introduction
guide that comes with the RM kit.
Chapter 3
Chapter 4
and
Site Requirements and Prerequisites
.
Chapter 6
Site Requirements and Prerequisites
Rack Mounting Kit for
.
2-1