User Guide
Each SAS port in the following image matches the color of another set of drives in that specific zone
group. Connect the host servers to the enclosure using SAS cables in the Configuration listed in the table
below. The left side of the table displays the host connection and the right side displays the enclosure IOM
SAS port connection.
Table 48: SAS Cable connections for Configuration 2
Host connection (SAS Port)
Configuration 3:
Configuration 3 allows up to two redundantly configured hosts to view a specific zone group of drives.
Each host will be able to view up to 30 drives that are mapped to both IOMs. Each zone group will display
all of the devices that are contained within that zone. If a drive slot is not populated, it will still be part of
that zone group, but it will not display any results in enclosure management until the drive slot has been
populated. In this Configuration, the enclosure is divided into two zone groups as shown in the image
below represented by two different colors. Each zone group matches to three SAS ports on each side of
the rear IOM to allow for the connections to two different hosts.
• In-band management: Configuration 3 can be initiated in the sg_senddiag command in-band by
using 03 in the Zoning Configuration option. See:
senddiag commands.
• Out-of-band management: Configuration 3 can be initiated in the out-of-band management by using
3 in the ZoningConfig option. The following are example Redfish POST and cURL commands:
Enclosure IOM connection (SAS Port)
Host 1
Host 1
Host 1
Host 1
Host 2
Host 2
Host 2
Host 2
Host 3
Host 3
Host 3
Host 3
sg_senddiag Command (page 188)
5. System Management
A1
A2
B1
B2
A3
A4
B3
B4
A5
A6
B5
B6