Rack
Configurations
Ultrastar® Data102
Regulatory Model: H4102-J
December 2020
Rev. 1.3
1ET1639

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultrastar Data102 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Western Digital Ultrastar Data102

  • Page 1 Recommended Rack Configurations Ultrastar® Data102 Regulatory Model: H4102-J December 2020 Rev. 1.3 1ET1639...
  • Page 2: Table Of Contents

    Table of Contents Revision History............................ii Points of Contact..........................iii Notices..............................iv Chapter 1. Overview......................1 Ultrastar Data102 Rack Requirements....................2 Rack Safety............................3 CMA Standard Recommended Racks....................4 CMA Lite Recommended Racks......................5 Vertical Rack Rail Settings........................6 Recommended PDUs and Available Installation Space..............7 Chapter 2.
  • Page 3: Revision History

    Recommended Rack Revision History Configurations Revision History Date Revision Comment March 2018 Revision 1.0 Initial Release February 2019 Revision 1.1 Added CMA Lite December 2019 Revision 1.2 Rebranded document to WD design December 2020 Revision 1.3 Added UK Import Representation Contact...
  • Page 4: Points Of Contact

    Email: support@wdc.com Website: https:/ /portal.wdc.com/Support/s/ UK Import Representation Contact Western Digital UK Limited Hamilton House, Regent Park, Kingston Road Leatherhead, Surrey KT22 7PL, GB, United Kingdom Telephone: +44 1372 366000...
  • Page 5: Notices

    Per Western Digital Terms and Conditions of Sale, the user of Western Digital products in life support applications assumes all risk of such use and indemnifies Western Digital against all damages.
  • Page 6: Chapter 1. Overview

    Western Digital Overview This section provides an overview of rack requirements and recommendations. In This Chapter: - Ultrastar Data102 Rack Requirements..2 - Rack Safety............. 3 - CMA Standard Recommended Racks...4 - CMA Lite Recommended Racks....5 - Vertical Rack Rail Settings......6 - Recommended PDUs and Available Installation Space..........7...
  • Page 7: Ultrastar Data102 Rack Requirements

    1.1   Ultrastar Data102 Rack Requirements The Ultrastar Data102 is designed to be installed into a rack that meets the EIA-310 standard at a minimum 1181-1197 mm (46.5in. - 47.13in.) of usable rack space, frame to frame. The vertical rack rails must be set between 812.8mm - 914.4mm / 32 in.
  • Page 8: Rack Safety

    1.2   Rack Safety When extended out of the rack on the rail system, the Ultrastar Data102 will be ~950 mm / 37.4in. extended outward. This may be a potential tipping hazard depending on the configuration of the rack. Ensure that leveling feet, anti-tilt, and any other safety features recommended by the specific rack manufacturers have been deployed before servicing.
  • Page 9: Cma Standard Recommended Racks

    1.3 CMA Standard Recommended Racks Figure 2: Shipping Bracket Screw Locations 1.3   CMA Standard Recommended Racks The following is a list of racks that are recommended for the Ultrastar Data102 using CMA Standard. Table 2: Recommended Racks Rack Vendor...
  • Page 10: Cma Lite Recommended Racks

    H: in. x W: in. x D: in. w/ Rack Extender 1.4   CMA Lite Recommended Racks The following is a list of racks that are recommended for the Ultrastar Data102 using CMA Lite. Table 3: Recommended Racks Rack Vendor...
  • Page 11 1. Overview Recommended Rack Configurations 1.4 CMA Lite Recommended Racks Rack Vendor Part Number Dimensions Notes Units with the front door stiffeners or the door latch in the CMA Lite configuration. WEDIT604 H: 2178.1mm x W: 609.6mm x D: The enclosure 1317.6mm/ cannot be H: 85.75in.
  • Page 12: Vertical Rack Rail Settings

    1. Overview Recommended Rack Configurations 1.5 Vertical Rack Rail Settings 1.5   Vertical Rack Rail Settings The vertical rack rails should be adjusted to the specified measurements in all of the recommended rack configurations to ensure the enclosure and cable management fit properly. After the front and rear vertical rack rails have been adjusted the enclosure rails can be extended or retracted to best fit these adjustments.
  • Page 13: Recommended Pdus And Available Installation Space

    Recommended Rack 1. Overview Configurations 1.6 Recommended PDUs and Available Installation Space 1.6   Recommended PDUs and Available Installation Space The following is a list of available PDU space that is recommended for use in each rack. Table 4: Available PDU Space Rack Model PDU Orientation...
  • Page 14 Recommended Rack 1. Overview Configurations 1.6 Recommended PDUs and Available Installation Space Figure 5: PDU in the Zero Space...
  • Page 15: Chapter 2. Cma Standard Rack Specifications

    Western Digital CMA Standard Rack Specifications This section provides information related to the recommended rack models, compatible PDUs, and required accessories and hardware using CMA Standard. Each rack recommendation comes with information specific to what PDUs are approved and what hardware is required to mount them.
  • Page 16: Crenlo/Emcor

    2. CMA Standard Rack Specifications Recommended Rack Configurations 2.1 CRENLO/EMCOR 2.1   CRENLO/EMCOR Table 5: Recommended CRENLO/EMCOR Rack Models Model Number Rack Units Dimensions AS-160099-03 H: 2060mm x W: 600mm x D: 1200mm / H: 81.1in. x W: 23.6in. x D: 47.2in. DC-42U2448-G H: 2057mm x W: 600mm x D: 1270mm / H: 80.9in.
  • Page 17: Tripp Lite

    2. CMA Standard Rack Specifications Recommended Rack Configurations 2.3 TRIPP LITE Model Number Rack Units Dimensions H: 96.25in. x W: 24in. x D: 51.8in. Table 9: Compatible PDUs Model Number Width Depth Orientation Server Technology STV-4501 55.5mm / 2.18in. 86.15mm / 3.39in. Rear STV-4502 55.5mm / 2.18in.
  • Page 18: Apc/Schneider

    2. CMA Standard Rack Specifications Recommended Rack Configurations 2.4 APC/Schneider Table 13: Compatible PDUs Model Number Width Depth Orientation Server Technology STV-4501 55.5mm / 2.18in. 86.15mm / 3.39in. Rear STV-4502 55.5mm / 2.18in. 86.15mm / 3.39in. Rear STV-4503 55.5mm / 2.18in. 86.15mm / 3.39in.
  • Page 19: Chapter 3. Cma Lite Rack Specifications

    Western Digital CMA Lite Rack Specifications This section provides information related to the recommended rack models, compatible PDUs, and required accessories and hardware using CMA Lite. Each rack recommendation comes with information specific to what PDUs are approved and what hardware is required to mount them.
  • Page 20: Crenlo/Emcor

    3. CMA Lite Rack Specifications Recommended Rack Configurations 3.1 CRENLO/EMCOR 3.1   CRENLO/EMCOR Table 18: Recommended CRENLO/EMCOR Rack Models Model Number Rack Units Dimensions AS-160099-03 H: 2060mm x W: 600mm x D: 1200mm / H: 81.1in. x W: 23.6in. x D: 47.2in. DC-42U2448-G H: 2057mm x W: 600mm x D: 1270mm / H: 80.9in.
  • Page 21: Tripp Lite

    3. CMA Lite Rack Specifications Recommended Rack Configurations 3.3 TRIPP LITE Model Number Rack Units Dimensions H: 96.25in. x W: 24in. x D: 51.8in. Table 22: Compatible PDUs Model Number Width Depth Orientation Server Technology STV-4501 55.5mm / 2.18in. 86.15mm / 3.39in. Rear STV-4502 55.5mm / 2.18in.
  • Page 22: Apc/Schneider

    3. CMA Lite Rack Specifications Recommended Rack Configurations 3.4 APC/Schneider Table 26: Compatible PDUs Model Number Width Depth Orientation Server Technology STV-4501 55.5mm / 2.18in. 86.15mm / 3.39in. Rear STV-4502 55.5mm / 2.18in. 86.15mm / 3.39in. Rear STV-4503 55.5mm / 2.18in. 86.15mm / 3.39in.
  • Page 23: Chapter 4. Installation

    Western Digital Installation In This Chapter: - PDU Mounting Bracket Installation (KIT- MBVPT-1B)............19 - PDU Mounting Bracket Installation (KIT- MB-40).............25...
  • Page 24: Pdu Mounting Bracket Installation (Kit-Mbvpt-1B)

    Recommended Rack 4. Installation Configurations 4.1 PDU Mounting Bracket Installation (KIT-MBVPT-1B) 4.1   PDU Mounting Bracket Installation (KIT-MBVPT-1B) The installation of PDU mounting bracket kit (KIT-MBVPT-1B) for the AFCO, TRIPPLITE, and CRENLO racks extends the PDUs farther back in the rack to allow for more room for the CMA and enclosure. Note: For recommended vertical rack rail settings, see: Vertical Rack Rail Settings (page Table 31: Procedure Info...
  • Page 25 Recommended Rack 4. Installation Configurations 4.1 PDU Mounting Bracket Installation (KIT-MBVPT-1B) Figure 7: Flat Bracket Installation (bottom) d. Align the right-angle bracket behind the flat bracket over the holes on the left-hand side of the flat bracket. e. Slide the washers onto the mounting bolts and secure the right-angle bracket to the backer plate through the flat bracket.
  • Page 26 Recommended Rack 4. Installation Configurations 4.1 PDU Mounting Bracket Installation (KIT-MBVPT-1B) Figure 9: Right-Angle Bracket Installed (bottom) Figure 10: Flush Right-Angle Bracket (bottom) Step 2 : Install the top side bracket using the provided hardware. a. Locate the two screw holes at the top of the back side of the PDU. b.
  • Page 27 Recommended Rack 4. Installation Configurations 4.1 PDU Mounting Bracket Installation (KIT-MBVPT-1B) Figure 11: Flat Bracket (top) c. Secure the flat bracket to the PDU by using the screws provided in the PDU mounting kit as shown in the image below. Figure 12: Flat Bracket Installation (top) d.
  • Page 28 Recommended Rack 4. Installation Configurations 4.1 PDU Mounting Bracket Installation (KIT-MBVPT-1B) Figure 13: Right-Angle Bracket Installation (top) Figure 14: Right-Angle Bracket Installed (top)
  • Page 29 Recommended Rack 4. Installation Configurations 4.1 PDU Mounting Bracket Installation (KIT-MBVPT-1B) Figure 15: Flush Right-Angle Bracket (top) Step 3 : Install the PDU into the rear of the rack. a. Locate the top row of holes on the top vertical rail. b.
  • Page 30: Pdu Mounting Bracket Installation (Kit-Mb-40)

    Recommended Rack 4. Installation Configurations 4.2 PDU Mounting Bracket Installation (KIT-MB-40) Figure 17: PDU Installation (bottom) Figure 18: PDU Distance from Rack Rear Rail 4.2   PDU Mounting Bracket Installation (KIT-MB-40) The installation of PDU mounting bracket kit (KIT-MB-40) for the AFCO, TRIPPLITE, and CRENLO racks extends the PDUs farther back in the rack to allow for more room for the CMA and enclosure.
  • Page 31 Recommended Rack 4. Installation Configurations 4.2 PDU Mounting Bracket Installation (KIT-MB-40) Note: For recommended vertical rack rail settings, see: Vertical Rack Rail Settings (page Table 32: Procedure Info # of People Required Tools Required Parts Required • # 2 Philips Screwdriver •...
  • Page 32 Recommended Rack 4. Installation Configurations 4.2 PDU Mounting Bracket Installation (KIT-MB-40) Figure 19: Locate PDU Mounting Buttons b. Remove the screws that secure the PDU mounting buttons using the # 2 Philips Screwdriver. Step 2 : Mount the PDU mounting buttons onto the angle-bracket. a.
  • Page 33 Recommended Rack 4. Installation Configurations 4.2 PDU Mounting Bracket Installation (KIT-MB-40) Figure 20: Install the PDU Mounting Button onto the Angle Bracket b. Repeat the previous step to install the PDU mounting button on the remaining angle-bracket. Step 3 : Install the angle-bracket to the bottom of the PDU using the provided hardware. a.
  • Page 34 Recommended Rack 4. Installation Configurations 4.2 PDU Mounting Bracket Installation (KIT-MB-40) Figure 21: Install the Angle Bracket on the PDU (Bottom) Step 4 : Install the angle-bracket to the top of the PDU using the provided hardware. a. Locate the two screw holes at the top of the back side of the PDU. b.
  • Page 35 Recommended Rack 4. Installation Configurations 4.2 PDU Mounting Bracket Installation (KIT-MB-40) Figure 22: Install the Angle Bracket on the PDU (Top) Step 5 : Install the PDU into the rear of the rack. a. Locate the middle set of keyholes on the rear vertical rack rails. b.
  • Page 36 Recommended Rack 4. Installation Configurations 4.2 PDU Mounting Bracket Installation (KIT-MB-40) Figure 23: Align PDU with Keyholes...
  • Page 37 Recommended Rack 4. Installation Configurations 4.2 PDU Mounting Bracket Installation (KIT-MB-40) Figure 24: PDU Installed into Keyholes c. Verify that the PDU is secure by pressing on the front of the PDU. If the PDU does not shift, it is properly mounted. If the PDU does shift, remove the PDU and repeat the PDU installation step to ensure it is secure.