Pump Seizing (Dtc P1274 / 523539-2, P1275 / 523540-2) - Kubota V3800-CR-TE4 Diagnosis Manual

Common rail system
Hide thumbs Also See for V3800-CR-TE4:
Table of Contents

Advertisement

V3800-CR-TE4,V3800-CR-TIE4, DM

(33) Pump Seizing (DTC P1274 / 523539-2, P1275 / 523540-2)

P1274 / 523539-2: Pump seizing 1
Behaviour during malfunction:
• Insufficient output
• Worsening exhaust gas performance
Detection item:
• High pressure 1 error
DTC set preconditions:
• Sensor supply voltage VCC# is normal
• Rail pressure sensor is normal
DTC set parameter (Approximate parameter):
• Rail pressure of 230 MPa (2350 kgf/cm
-1
500 min
(rpm)
[Threshold changes depending on the engine speed. 2600 min
Engine warning light:
• ON
System action:
• Output limitation: Approximately 50 % of normal condition
• Speed limitation (Accelerator limitation: 50 %)
• Rail pressure limitation: Command pressure ≤ 80 MPa (820 kgf/cm
• EGR stop
Recovery from error:
• Key switch turn OFF
P1275 / 523540-2: Pump seizing 2
Behaviour during malfunction:
• Insufficient output
• Worsening exhaust gas performance
Detection item:
• High pressure 2 error
DTC set preconditions:
• Sensor supply voltage VCC# is normal
• Rail pressure sensor is normal
DTC set parameter (Approximate parameter):
• Rail pressure of above 197 MPa (2010 kgf/cm
total time for 35 seconds
[Threshold changes depending on the engine speed. 2600 min
• Or, rail pressure of above 220 MPa (2250 kgf/cm
-1
of below 500 min
(rpm)
[Threshold changes depending on the engine speed. 200 min
Engine warning light:
• ON
System action:
• Output limitation: Approximately 50 % of normal condition
• Speed limitation (Accelerator limitation: 50 %)
• Rail pressure limitation: Command pressure ≤ 80 MPa (820 kgf/cm
• EGR stop
Recovery from error:
• Key switch turn OFF
2
, 33400 psi) or more continues 1 second under the condition of above
-1
(rpm) should be used as a reference]
2
, 28600 psi), and below 80 MPa (820 kgf/cm
-1
(rpm) should be used as a reference]
2
, 31900 psi) continues total time for 1 second under condition
-1
(rpm) should be used as a reference]
1-S220
COMMON RAIL SYSTEM
2
, 12000 psi)
9Y1200192CRS0779US0
2
, 12000 psi) continues
2
, 12000 psi)
9Y1200192CRS0780US0