V3800-CR-TE4,V3800-CR-TIE4, DM
Name
ISO 14229
P-Code
SPN
J1939-73
FMI
Emergency
DTC Name
Exhaust gas temperature sensor 0: High
Management Unit
for Detected Part
Detection item
DTC Set
Preconditions
DTC set parameter
Time to action or
number of error
detection
System Action
Behaviour During
Malfunction
Engine Warning
Light
Recovery from
error
Exhaust gas temperature sensor 0:
Emergency high
P3002
4765
0
EXTEMPT0
• DOC inlet temperature (T0) high
• Exhaust gas temperature sensor T0,T1
and T2 are normal
• Battery voltage is normal
• DOC inlet temperature (T0): 700 °C
(1292 °F) or more
• 2.0 sec. or more
• Stop injection (Q = 0 mm
• Engine stop
• Inhibit starter relay activation until
exhaust gas temperature reduces down
to 300 °C
(572 °F)
• Engine stops
• Inhibitef cranking until down to 300 °C
(572 °F)
• ON
• Under 300 °C (572 °F) & key switch turn
OFF
Exhaust gas temperature sensor 1:
Emergency
Exhaust gas temperature sensor 1: High
• DPF inlet temperature (T1) high
• Exhaust gas temperature sensor T0,T1
and T2 are normal
• Battery voltage is normal
• DPF inlet temperature (T1): 715 °C
(1319 °F) or more
• 9.0 min. or more
3
/st)
• Stop injection (Q = 0 mm
• Engine stop
• Inhibit starter relay activation until
exhaust gas temperature reduces down
to 300 °C
(572 °F)
• Engine stops
• Inhibitef cranking until down to 300 °C
(572 °F)
• ON
• Under 300 °C (572 °F) & key switch turn
OFF
1-S112
COMMON RAIL SYSTEM
Emergency high
P3003
3242
0
EXTEMPT1
3
/st)
9Y1200192CRS0652US0
KiSC issued 05, 2012 A