V3800-CR-TE4,V3800-CR-TIE4, DM
Name
ISO 14229
P-Code
SPN
J1939-73
FMI
DTC Name

Pressure limiter emergency open

Management Unit
for Detected Part
Detection item
DTC Set
Preconditions
A: Fuel leak (P0093) is detected
B: Condition (1) or (2) is fulfilled;
DTC set parameter
(1) Rail pressure exceeds 191 MPa (1950 kgf/cm
(2) Within 1 sec, after the rail pressure goes below 191 MPa (1950 kgf/cm
Time to action or
number of error
detection
System Action
Behaviour During
Malfunction
Engine Warning
Light
Recovery from
error
• Pressure limiter emergency open
• Rail pressure sensor is normal
• Sensor supply voltage VCC# is normal
• Combination of below A and B
[Before the pressure decrease, the rail pressure is above 191 MPa (1950 kgf/cm
27700 psi)]
• 1 time or more
• Output limitation: Approximately 50 % of normal condition
• Speed limitation (Accelerator limitation: 50 %)
• Rail pressure limitation:
Command pressure ≤ 80 MPa (820 kgf/cm
• EGR stop
• Insufficient output
• Worsening exhaust gas performance
• ON
• Key switch turn OFF
Pressure limiter emergency open
P0087
633
7
PLACT
2
, 27700 psi)
2
, 12000 psi)
1-S69
COMMON RAIL SYSTEM
2
, 27700 psi)
2
,
9Y1200192CRS0609US0