Kubota V3800-CR-TE4 Diagnosis Manual page 199

Common rail system
Hide thumbs Also See for V3800-CR-TE4:
Table of Contents

Advertisement

V3800-CR-TE4,V3800-CR-TIE4, DM
1. Check the Coolant Temperature Sensor Characteristics for
An Error
1. Refer to DTC P0117, P0118, and check the ECU, wiring
harness and sensor for an error.
OK
Check the cooling system. → Repair the faulty area.
If the cooling system is operating normally, ask the user about
malfunction occurrence based on the freeze-frame data to determine
whether or not the system was used improperly.
NG
Check and repair or replace the faulty parts.
(1) CAN1 Connector
(2) Terminal THW
(3) Terminal A-GND2
1-S172
COMMON RAIL SYSTEM
(a) Terminal Layout
9Y1200192CRS0708US0
KiSC issued 05, 2012 A