Name
ISO 14229
P-Code
SPN
J1939-73
FMI
DTC Name

Excessive PM4

Management Unit
for Detected Part
Detection item
DTC Set
Preconditions
DTC set parameter
Time to action or
number of error
detection
System Action
Behaviour During
Malfunction
Engine Warning
Light
Recovery from
error
Excessive PM4
P3007
3701
16
DPFPMEX3
• PM accumulation level4
• Battery voltage is normal
• PM accumulation more than trigger level
(31000 mg)
• Transient
• Output limitation: Approximately 50 % of
normal condition
• Insufficient output
• ON
• Diagnostic counter = zero

Excessive PM5

• PM accumulation level5
• Battery voltage is normal
• PM accumulation more than trigger level
(36000 mg)
• Transient
• Output limitation: Approximately 50 % of
normal condition
• Insufficient output
• ON
• Key switch turn OFF
1-S115
COMMON RAIL SYSTEM
Excessive PM5
P3008
3701
0
DPFPMEX4
9Y1200192CRS0655US0
KiSC issued 05, 2012 A