Exhaust Gas Temperature Sensor 2: Emergency High - Kubota V3800-CR-TE4 Diagnosis Manual

Common rail system
Hide thumbs Also See for V3800-CR-TE4:
Table of Contents

Advertisement

V3800-CR-TE4,V3800-CR-TIE4, DM
Name
ISO 14229
P-Code
SPN
J1939-73
FMI
Emergency
DTC Name
Exhaust gas temperature sensor 2: High
Management Unit
for Detected Part
Detection item
DTC Set
Preconditions
DTC set parameter
Time to action or
number of error
detection
System Action
Behaviour During
Malfunction
Engine Warning
Light
Recovery from
error

Exhaust gas temperature sensor 2: Emergency high

• DPF outlet temperature (T2) high
• Exhaust gas temperature sensor T0,T1 and T2 are normal
• Battery voltage is normal
• DPF outlet temperature (T2): 820 °C (1508 °F) or more
• 2.0 sec. or more
• Stop injection (Q = 0 mm
• Engine stop
• EGR stop
• Intake throttle 0 % open (Close)
• Inhibit starter relay activation until exhaust gas temperature reduces down to 300 °C
(572 °F)
• Engine stops
• Inhibitef cranking until down to 300 °C (572 °F)
• ON
• Under 300 °C (572 °F) & key switch turn OFF
P3004
3246
0
EXTEMPT2
3
/st)
1-S113
COMMON RAIL SYSTEM
9Y1200192CRS0653US0
KiSC issued 05, 2012 A