Fuel Temperature Sensor Abnormality - Kubota V3800-CR-TE4 Diagnosis Manual

Common rail system
Hide thumbs Also See for V3800-CR-TE4:
Table of Contents

Advertisement

V3800-CR-TE4,V3800-CR-TIE4, DM
Name
ISO 14229
P-Code
SPN
J1939-73
FMI
DTC Name
Fuel temperature sensor: Low
Management Unit
for Detected Part
Detection item
DTC Set
Preconditions
DTC set parameter
Time to action or
number of error
detection
System Action
Behaviour During
Malfunction
Engine Warning
Light
Recovery from
error

Fuel temperature sensor abnormality

P0182
174
4
THFL
• Ground short circuit of sensor / harness
• Battery voltage is normal
• Voltage of temperature sensor in supply
pump is 0.1 V or less
• 2.8 sec. or more
• At start-up = −20 °C
(−4 °F) [default value]
• Under other conditions = 45 °C (113 °F)
[default value]
• None
• ON
• Diagnostic counter = zero
Fuel temperature sensor: High
• Open circuit or +B short circuit of sensor
/ harness
• Battery voltage is normal
• Voltage of temperature sensor in supply
pump is 4.9 V or above
• 2.8 sec. or more
• At start-up = −20 °C
(−4 °F) [default value]
• Under other conditions = 45 °C (113 °F)
[default value]
• None
• ON
• Diagnostic counter = zero
1-S77
COMMON RAIL SYSTEM
P0183
174
3
THFH
9Y1200192CRS0617US0
KiSC issued 05, 2012 A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V3800-cr-tie4

Table of Contents