V3800-CR-TE4,V3800-CR-TIE4, DM
Name
ISO 14229
P-Code
SPN
J1939-73
FMI
DTC Name
Excessive PM3
Management Unit
for Detected Part
Detection item
DTC Set
Preconditions
DTC set parameter
Time to action or
number of error
detection
System Action
Behaviour During
Malfunction
Engine Warning
Light
Recovery from
error
• PM accumulation level3
• Battery voltage is normal
• PM accumulation more than trigger level (26000 mg)
• Transient
• Output limitation: Approximately 50 % of normal condition
• Insufficient output
• ON
• Diagnostic counter = zero
Excessive PM3
P3006
3701
15
DPFPMEX2
1-S114
COMMON RAIL SYSTEM
9Y1200192CRS0654US0
KiSC issued 05, 2012 A