V3800-CR-TE4,V3800-CR-TIE4, DM
2. Check the Voltage Between Camshaft Position Sensor
Terminals
1. Place the key switch in the OFF position, and unplug the
camshaft position sensor connector from the socket.
2. Place the key switch in the ON position, and measure the
voltage between G-VCC and G-GND terminals at the wiring
harness side.
Factory
Approx. 5 V
specification
OK
Go to "3. Check the Connectors".
NG
Go to "5. Measure the ECU Terminal Voltage".
(1) Terminal G-VCC
(2) Terminal G
(3) Terminal G-GND
3. Check the Connectors
1. Check the sensor and wiring harness connectors for incorrect
connection, inappropriate fitting, poor contact or other faulty
areas.
Factory
Must be free from incorrect connection, inappropriate fitting,
specification
poor contact.
OK
Go to "4. Check the Wiring Harness".
NG
Repair or replace.
(1) Terminal G-VCC
(2) Terminal G
(3) Terminal G-GND
4. Check the Wiring Harness
1. Check the wiring harness between G terminal of sensor and
ECU for a short or an open circuit.
Factory
Must be free from shorts and open circuit.
specification
OK
The sensor has abnormality. → Replace.
NG
Repair.
(1) Terminal G-VCC
(2) Terminal G
(3) Terminal G-GND
1-S185