Calibration; Calibrate Automatically - HIKVISION DS-2TD2137-7P User Manual

Thermal network camera
Hide thumbs Also See for DS-2TD2137-7P:
Table of Contents

Advertisement

DS-2TD2137-7P Thermal Network Camera User Manual
Target Marking Color: The frame color of human is shown as orange, the frame color of vehicle is
shown as purple.
Display Target Info.on Alarm Picture: Select to display the target information on the alarm picture.
Display Rule Info.on Alarm Picture: Select to display the rule information on the alarm picture.
Snapshot Settings: Select to upload the picture to the surveillance center when the VCA alarm
occurs.You can also set the quality and resolution of the picture separately.
2. Click Save.
3. Go to Configuration → Local , check Enable rules to display rules information on live view.

Calibration

Calibrate Automatically

Before You Start
Make sure to know the actual height of the target person in the scene.
Make sure there are no moving objects in the view except for the person.
Steps
1. Go to Configuration → VCA → Camera Calibration.
2. Check Camera Calibration.
3. When the person is totally seen in live view, enter the person's height in Target Height.
NOTE:
You can set a maximum of two decimal places.
4. Click
to start calibration.
CAUTION: Auto calibration starts when the person is totally seen in live view, and ends when
the person is in the endpoint.
The endpoint-to-camera distance (m) equals four times the lens focal length (mm).
E.g, for a 7 mm lens, the recommended endpoint is 28 m (7 x 4).
The person should walk in a zig-zag path, and two zig-zag paths are required.
Make sure the walking route covers the left, middle, right of image.
The auto calibration duration should be no shorter than 10 sec, and no longer than
10 min. The device will stop calibration automatically if the duration is too long.
If there is a moving object such as a leaf or tree in the scene, you can set the
shielded area. Refer to Set Shielded Region for setting details.
5. When the person exits, click
UM DS-2TD2137-7P 042021NA
to stop calibration.