7.3.3 Set Overlay & Capture Parameters
Steps
1. Go to Configuration → Perimeter Protection → Overlay & Capture .
Display VCA Info. on Stream
Select to display target info and rule on stream, the information will be added to the video
stream, and the overlay will be displayed if you get live view or play back by the VS Player.
Display Trajectory
The target's moving path will be shown in live view.
Display Target Info. on Alarm Picture
Select to display the target information on the alarm picture.
Display Rule Info. on Alarm Picture
Select to display the rule information on the alarm picture.
Display Size Info. on Alarm Picture
Select to display the size information of the target on the alarm picture.
Snapshot Settings
Select to upload the picture to the surveillance center when the alarm occurs. You can also
set the quality and resolution of the picture separately.
2. Click Save.
Go to Configuration → Local , check Enable rules to display rules information on the live view.

7.3.4 Calibration

You can calibrate the camera first to improve the detection accuracy of perimeter protection. The
calibration is optional, take the actual condition for reference.
Note
The function varies according to different camera models.
Calibrate Automatically
Before You Start
Make sure that we have known the actual height of the target person in the scene.
Make sure there is no moving objects in the view except for the person.
Steps
1. Go to Configuration → Perimeter Protection → Camera Calibration .
2. Check Camera Calibration.
3. When the person is totally seen in live view, enter the height of person in Target Height.