DS-2TD2137-7P Thermal Network Camera User Manual
Chapter 3 Temperature Measurement
When you enable this function, the device measures the actual temperature of the scene. It alarms when
temperature exceeds the temperature threshold value.
3.1
Notice
This section introduces configuring the temperature measurement function.
•
The target surface should be as vertical to the optical axis as possible. It is recommended that the
angle of oblique image plane should be less than 45°.
•
The target image pixels should be more than 5 × 5.
•
If multiple presets will be taken for temperature measurement, it is recommended to set the patrol
time above 20 s.
•
Select line thermography or area thermography for a certain area temperature measurement. Point
thermography is not recommended in case deviation occurs during device movement that might affect
the temperature measurement accuracy.
3.2
Thermography Configuration Flow Chart
This section introduces configuring temperature measurement.
NOTE:
Refer to the
UM DS-2TD2137-7P 042021NA
Figure 1, Thermography Configuration Flow Chart
Quick Start Guide
for detailed Installation information in the flow chart.
13