Search Security Audit Logs
You can search and analyze the device security log files to find illegal intrusion and troubleshoot security
events.
Steps
NOTE:
This function is supported only by certain camera models.
1. Go to Configuration → System → Maintenance → Security Audit Log.
2. Select log types, Start Time, and End Time.
3. Click Search. The log files that match the search conditions will be displayed on the Log List.
4. Optional: Click Export to save the log files to your computer.
Set IP Address Filter
IP address filter is a tool for access control. You can enable the IP address filter to allow or forbid visits
from certain IP addresses.
NOTE:
IP address refers to IPv4.
Steps
1. Go to Configuration → System → Security → IP Address Filter.
2. Check Enable IP Address Filter.
3. Select the type of IP address filter.
•
Forbidden: IP addresses in the list cannot access the device.
•
Allowed: Only IP addresses in the list can access the device.
4. Edit the IP address filter list.
•
Add: Add a new IP address to the list.
•
Modify: Modify the selected IP address in the list.
•
Delete: Delete the selected IP address in the list.
5. Click Save.
Set SSH
SSH is a protocol to ensure remote login security.This setting is reserved for professional maintenance
personnel only.
Steps
1. Go to Configuration → System → Security → Security Service.
UM DS-2TD2137-7P 042021NA