Chapter 4 Fire Source Detection; Select Recommended Scene; Set Fire Detection Parameters - HIKVISION DS-2TD2137-7P User Manual

Thermal network camera
Hide thumbs Also See for DS-2TD2137-7P:
Table of Contents

Advertisement

DS-2TD2137-7P Thermal Network Camera User Manual

Chapter 4 Fire Source Detection

The device will trigger and upload alarms when it detects a fire source or smoking.
Fire source detection includes fire source detection and smoking detection. It is applied for fire-
prevention purposes in scenic regions, foresst, tunnels, etc.
Fire Detection
Configure the fire source detection parameters. If a fire source is detected, the alarm actions will trigger.
Smoking Detection
The device can detect smoking behavior and output an alarm.

Select Recommended Scene

Introduce the recommended scenes of fire source detection and help you select the appropriate scene.
Fire source detection can be applied to indoor and outdoor monitoring with a 15 km maximum detection
radius. To achieve the best monitoring effect, set the installation location as per requirements below.
The installation location should be the highest position within the detection area. The lens should not
be covered during movement to detect the maximum area.
It is better to choose an installation location with convenient traffic, well-equipped power, and
Internet facilities (e.g., communication tower, watchtower, high-rise roof, etc.).

Set Fire Detection Parameters

To avoid potential fire damage, configure the fire detection function for certain areas. Detailed
configuration steps are shown below.
Before You Start
Go to Configuration → System → Maintenance → VCA Resource Type, select Temperature
Measurement+Behavior Analysis or Temperature Measurement+Fire Detection.
Steps
1. Go to Configuration → Local.
2. Check Locate Highest Temperature Point to display the position of highest temperature. Check Frame
Fire Point to frame the fire source on live view.
3. Go to Configuration → Event → Smart Event, select Dynamic Fire Source Detection.
4. Check Enable Dynamic Fire Source Detection.
5. Set the fire detection parameters.
Fire Source Detection Mode
Smoking Mode: Detect smoking behavior in the scene.
UM DS-2TD2137-7P 042021NA
18

Advertisement

Table of Contents
loading

Table of Contents