DS-2TD2137-7P Thermal Network Camera User Manual
Area Thermography
Configure the temperature measurement rule and monitor the maximum temperature of the area.
Steps
1. Click and drag the mouse in live view to draw the area, and right click to finish drawing.
2. Click and move the area to adjust the position.
3. Drag the corners of the area to adjust the size and shape.
4. Go to the Live View interface to view the maximum temperature and rule of the area in the thermal
channel.
Set Shielded Region
You can configure areas from being detected.
Steps
1. Check Enable Shield Area.
2. Click
.
3. Drag the mouse in live view to draw the area. Drag the red rectangle corners to change shape and size.
4. Right click the mouse to stop drawing.
5. Optional: Select one area and click
6. Click Save.
Manual Thermography
Enable manual thermography on the device to click any position on live view to show the real temperature.
Steps
1. Go to Configuration → Local and set Display Temperature Info. as Yes.
2. Go to Configuration → Temperature Measurement → Basic Settings.
3. Check Enable Temperature Measurement.
4. Click Save.
5. Go to live view, select the thermal channel, and click
real temperature.
UM DS-2TD2137-7P 042021NA
to delete it.
. Click any position on the interface to show the
17