5.2 Set VCA Parameters

Steps
1. Go to Configuration → VCA → Basic Settings.
Display VCA Info. on Stream
Select to display target info and rule on stream, the information will be added to the video
stream, and the overlay will be displayed if you get live view or play back by the VS Player.
Display Trajectory
The target's moving path will be shown in live view.
Target Marking Color
The frame color of human is shown as orange, the frame color of vehicle is shown as purple.
Display Target Info. on Alarm Picture
Select to display the target information on the alarm picture.
Display Rule Info. on Alarm Picture
Select to display the rule information on the alarm picture.
Snapshot Settings
Select to upload the picture to the surveillance center when the VCA alarm occurs. You can
also set the quality and resolution of the picture separately.
2. Click Save.
Go to Configuration → Local, check Enable rules to display rules information on the live view.

5.3 Calibration

5.3.1 Calibrate Automatically

Before You Start
● Make sure that we have known the actual height of the target person in the scene.
● Make sure there is no moving objects in the view except for the person.
Steps
1. Go to Configuration → VCA → Camera Calibration.
2. Check Camera Calibration.
3. when the person is totally seen in live view, enter the height of person in Target Height.
Note
You can set a maximum of two decimal places.