DS-2TD2137-7P Thermal Network Camera User Manual
Single Alarm: The system sends alarm only once for one target triggering. Otherwise, the alarm will
trigger continuously until the target disappears.
Scene Modes: The scene mode is set to be General by default. Select Distant View when you are far
from the targets. Select Indoor when you are indoor.
Restore Parameters
Restore Default: Click Restore to restore the parameters to the default.
Restart VCA: Click Restart to restart the VCA function.

Set Global Size Filter

Targets larger or smaller than the set size range are filtered out. The settings is valid for all behavior
analysis rules.
Steps
1. Go to Configuration → Behavior Analysis → Advanced Configuration to enable the function.
2. Click
to draw a maximum size frame on live image.
3. Click
to draw a minimum size frame on live image.
4. Click Save.