DS-2TD2137-7P Thermal Network Camera User Manual
Version: View the version of the current algorithm.
4. Click Save.

Set Normal Mode

This function measures the temperature of the whole scene and alarm.
Steps
1. Go to Configuration → Temperature Measurement → Basic Settings, and check Enable Temperature
Measurement.
2. Refer to Set Thermography Parameters to set the parameters.
3. Go to Configuration → Temperature Measurement → Advanced Settings, and select Normal.
4. Configure the normal mode parameters.
Emissivity: Set the emissivity of your target. The emissivity of each object is different.
Distance: The distance between the target and the device.
Pre-Alarm Threshold: When the target temperature exceeds the pre-alarm threshold, and this
status keeps more than Filtering Time, it triggers a pre-alarm.
Alarm Threshold: When the target temperature exceeds the alarm threshold, and this status keeps
more than Filtering Time, it triggers an alarm.
Pre-Alarm Output and Alarm Output: Check Pre-Alarm Output and Alarm Output to link the pre-
alarm or alarm with the connected alarm device.
5. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for setting
linkage method.
6. Click Save.
NOTE:
The maximum and minimum temperature will be displayed on live view.
7. Go to Image → VCA Rules Display to adjust the fonts size and the temperature color of normal, alarm,
and pre-alarm.

Object Missing

This object is not available in the repository.

Set Thermography Rule

Steps
1. Customize the rule name.
2. Select the rule type to Point, Line, or Area. Then draw a point, line, or area on the interface where the