Renesas M30245 Series User Manual page 279

16-bit single-chip microcomputer
Hide thumbs Also See for M30245 Series:
Table of Contents

Advertisement

M30245 Group
Interrupt control register (Note 1)
b7
b6
b5
b4
b7
b6
b5
b4
0
Figure 2.15.2. Interrupt control registers
Rev.2.00 Oct 16, 2006
REJ09B0340-0200
Symbol
Address
KUPIC
0041
S2RIC
0042
S13BCNIC
0043
TA1IC
0045
EP0IC
0046
TA2IC
0047
S0RIC
004A
ADIC
004B
DM0IC
004C
S3TIC
004D
DM1IC
004E
b3
b2
b1
b0
S2TIC
004F
DM2IC
0050
Bit symbol
Interrupt priority level
ILVL0
select bit
ILVL1
ILVL2
IR
Interrupt request bit
Nothing is assigned. Write "0" when writing to these bits.
The contents are indeterminate if read.
Symbol
INT1IC
S1RIC
b3
b2
b1
b0
S02BCNIC
INT2IC
INT0IC
Bit symbol
ILVL0
Interrupt priority level
select bit
ILVL1
ILVL2
IR
Interrupt request bit
POL
Polarity select bit
Reserved bit
Nothing is assigned. Write "0" when writing to these bits.
The contents are indeterminate if read.
Note 1: To rewrite the interrupt control register, do so at a point that dose not generate the
interrupt request for that register. For details, see the precautions for interrupts.
Note 2: This bit can only be reset (=0), but cannot be set (=1).
Note 3: For S1RIC ( 0048
page 268 of 354
When reset
XXXXX000
16
2
XXXXX000
16
2
XXXXX000
16
2
XXXXX000
16
2
XXXXX000
16
2
XXXXX000
16
2
XXXXX000
16
2
XXXXX000
16
2
XXXXX000
16
2
XXXXX000
16
2
XXXXX000
16
2
XXXXX000
16
2
XXXXX000
16
2
Bit name
b2 b1 b0
0 0 0 : Level 0 (interrupt disabled)
0 0 1 : Level 1
0 1 0 : Level 2
0 1 1 : Level 3
1 0 0 : Level 4
1 0 1 : Level 5
1 1 0 : Level 6
1 1 1: Level 7
0 : Interrupt not requested
1 : Interrupt requested
Address
0044
16
0048
16
0049
16
005E
16
005F
16
Bit name
b2 b1 b0
0 0 0 : Level 0 (interrupt disabled)
0 0 1 : Level 1
0 1 0 : Level 2
0 1 1 : Level 3
1 0 0 : Level 4
1 0 1 : Level 5
1 1 0 : Level 6
1 1 1: Level 7
0 : Interrupt not requested
1 : Interrupt requested
0 : Selects falling edge
1 : Selects rising edge
Always set to "0"
) and S02BCNIC ( 0049
), "0" should always be written.
16
16
2. Multiple Interrupts
Symbol
Address
When reset
S1TIC
0051
XXXXX000
16
DM3IC
0052
XXXXX000
16
S0TIC
0053
XXXXX000
16
TA0IC
0054
XXXXX000
16
S3RIC
0055
XXXXX000
16
SUSPIC
0056
XXXXX000
16
TA3IC
0057
XXXXX000
16
RSMIC
0058
XXXXX000
16
TA4IC
0059
XXXXX000
16
RSTIC
005A
XXXXX000
16
SOFIC
005B
XXXXX000
16
VBSIC
005C
XXXXX000
16
USBFIC
005D
XXXXX000
16
Function
R
W
(Note 2)
When reset
XX00X000
2
XX00X000
2
XX00X000
2
XX00X000
2
XX00X000
2
Function
W
R
(Note 2)
(Note 3)
2
2
2
2
2
2
2
2
2
2
2
2
2

Advertisement

Table of Contents
loading

This manual is also suitable for: