Pod probe for m30220 and m30221 group mcus

Advertisement

Quick Links

To our customers,
st
On April 1
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
Old Company Name in Catalogs and Other Documents
Renesas Electronics website:
http://www.renesas.com
st
April 1
, 2010
Renesas Electronics Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Renesas M30220T-PRB

  • Page 1 On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document, it is a valid Renesas Electronics document. We appreciate your understanding.
  • Page 2 Renesas Electronics. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as “Specific”...
  • Page 3 M30220T-PRB User’s Manual Pod Probe for M30220 and M30221 Group MCUs Rev.1.00 2003.09...
  • Page 4 • These materials are intended as a reference to assist our customers in the selection of the Renesas Technology product best suited to the customer's application; they do not convey any license under any intellectual property rights, or any other rights, belonging to Renesas Technology Corporation, Renesas Solutions Corporation or a third party.
  • Page 5: Precautions For Safety

    Preface The M30220T-PRB is a pod probe for M30220 and M30221 Groups of Renesas 16-bit microcom- puters. The M30220T-PRB is used by connecting to the PC4701 emulator main unit and the M30200T-RPD-E emulation pod main unit. This manual mainly explains specifications and setting up of M30220T-PRB. For detail information about the emulator main unit, emulation pod main unit, and emulator debugger, refer to each user's manual.
  • Page 6: Table Of Contents

    Contents Chapter 1. Precautions for Safety ... 6 1.1 Safety Symbols and Meanings ... 6 Chapter 2. Preparation ... 10 2.1 Package Components ... 10 2.2 Other Tool Products Required for Development ... 10 2.3 System Configuration ... 11 Chapter 3. Setting Up ... 14 3.1 Switch Settings ...
  • Page 7 Chapter 1. Precautions for Safety This chapter describes precautions for using this product safely and properly. For precautions for the emulator main unit, the emulation pod main unit and the emulator debugger, refer to each user's manual included with your product. 1.1 Safety Symbols and Meanings ...
  • Page 8: Chapter 1. Precautions For Safety

    Chapter 1. Precautions for Safety In both the user's manual and on the product itself, several icons are used to insure proper handling of this product and also to prevent injuries to you or other persons, or damage to your properties. This chapter describes the precautions which should be taken in order to use this product safely and properly.
  • Page 9: Note On Differences Between Actual Mcu And Emulator

    • The work area given below is assigned as the initial setting at the time of starting up the emulator debugger. (Set by "F/W and Work Area" tab* When using the pod probe M30220T-PRB for M30220 and M30221 Group MCUs, use the initial setting value.
  • Page 10: Note On Reading Out Sfr Area

    IMPORTANT Note on Reading Out SFR Area: • When reading out the registers below, they are not read out properly. However, they can be written properly. Pullup control register 2 Key input mode register ( 8 / 36 )
  • Page 11 Chapter 2. Preparation This chapter describes the package components, the system configuration and the preparation for using this product for the first time. 2.1 Package Components... 10 2.2 Other Tool Products Required for Development... 10 2.3 System Configuration ... 11 ( 9 / 36 )
  • Page 12: Chapter 2. Preparation

    M30220T-PRB Repair Request Sheet (English) M30220T-PRB Repair Request Sheet (Japanese) Please keep the M30220T-PRB’s packing box and cushion material in your place for reuse at a later time when sending your product for repair or other purposes. Always use these packing box and cushion material when transporting the M30220T-PRB.
  • Page 13: System Configuration

    Products (1) and (2) shown in Figure 2.1 are included with this product. Get (3) and (4) in Figure 2.1 separately. (1) Pod probe (M30220T-PRB) This pod probe is equipped with the evaluation MCUs M30220GP-EVA and M30220GP-PORT. (2) Pitch converter board for 144-pin 0.5mm-pitch LQFP (FLX-144NSD) Board for connecting the pod probe to the 144-pin 0.5mm-pitch LQFP foot pattern on the target...
  • Page 14 MEMO ( 12 / 36 )
  • Page 15 Chapter 3. Setting Up This chapter describes switch settings required for using this product and how to connect this product to the PC4701 and the target system. 3.1 Switch Settings ... 14 3.2 A-D Conversion Bypass Capacitor ... 15 3.3 Connecting M30200T-RPD-E ... 16 3.4 Connecting the Target System...
  • Page 16: Chapter 3. Setting Up

    Table 3.1 Switch settings of FLX64-PRB Function Selecting Selecting COUT pins for the target system COUT Switch No. As this switch is not used for M30220T-PRB, PORT Used when X COUT the target system (Factory-setting) ( 14 / 36 ) Switch setting is always selected.
  • Page 17: A-D Conversion Bypass Capacitor

    3.2 A-D Conversion Bypass Capacitor This product has foot patterns on the board for mounting a bypass capacitor for the A-D converter circuit. Mount a suitable bypass capacitor as occasion demands. Figure 3.2 shows the position of the bypass capacitor. Figure 3.2 Foot patterns of A-D conversion bypass capacitor Note on the Operation of A-D Converter: IMPORTANT...
  • Page 18: Connecting M30200T-Rpd-E

    3.3 Connecting M30200T-RPD-E The emulation pod for M30220 and M30221 Group MCUs consists of the M30200T-RPD-E and the M30220T-PRB. Figures 3.3 and 3.4 show how to connect the M30220T-PRB pod probe, and how to remove it, respectively. Figure 3.3 Connecting the M30220T-PRB pod probe Figure 3.4 Removing the M30220T-PRB pod probe...
  • Page 19: Connecting The Target System

    3.4 Connecting the Target System There are three ways available to connect the emulation pod to target systems as shown in Figure 3.5. Figure 3.5 Connecting the target system ( 17 / 36 )
  • Page 20 (1) Mount the NQPACK144SD (included) on the target. (2) Connect the YQPACK144SD (included) to the NQPACK144SD. Using a slotted head screw, secure the YQPACK144SD with the YQ-GUIDE's (included). (3) Connect the M30220T-PRB to the FLX-144NSD. (4) Connect the FLX-144NSD to the YQPACK144SD. ( 18 / 36 )
  • Page 21 (2) Connect the YQPACK144SE included with the FLX- 144NSE (separately available) to the NQPACK144SE. Using a slotted head screw, secure the YQPACK144SE with the YQ-GUIDE's (included). (3) Connect the M30220T-PRB to the FLX-144NSE (sepa- rately available). (4) Connect the FLX-144NSE (separately available) to the YQPACK144SE.
  • Page 22 (2) Connect the YQPACK120SE included with the FLX- 120NSE (separately available) to the NQPACK120SE. Using a slotted head screw, secure the YQPACK120SE with the YQ-GUIDE's (included). (3) Connect the M30220T-PRB to the FLX-120NSE (sepa- rately available). (4) Connect the FLX-120NSE (separately available) to the YQPACK120SE.
  • Page 23: Making An Mcu File For M3T-Pd30

    3.5 Making an MCU File for M3T-PD30 It is necessary to change the contents of the MCU file according to the MCU to be developed. Make the MCU file in the directory same as emulator debugger M3T-PD30 (M30220.MCU for M30220 Group MCU and M30221.MCU for M30221 Group MCU).
  • Page 24 MEMO ( 22 / 36 )
  • Page 25 This chapter describes specifications of this product. 4.1 Specifications ... 24 4.2 External Dimensions ... 25 (1) External Dimensions of Pod Probe ... 25 (2) External Dimensions of Converter Board (FLX-144NSD) ... 25 (3) External Dimensions of Converter Board (FLX-144NSE)... 26 (4) External Dimensions of Converter Board (FLX-120NSE)...
  • Page 26: Chapter 4. Specifications

    Chapter 4. Specifications 4.1 Specifications Table 4.1 lists the specifications of the M30220T-PRB. Table 4.1 Specifications of M30220T-PRB Emulators Emulation pod main unit Applicable MCUs Usable MCU mode Emulation memory Operating frequency Power supply range Stack capacity used for emulator...
  • Page 27: External Dimensions

    4.2 External Dimensions (1) External Dimensions of Pod Probe Figure 4.1 External dimensions of pod probe (2) External Dimensions of Converter Board (FLX-144NSD) Figure 4.2 shows the external dimensions and a sample foot pattern of the pitch converter board FLX- 144NSD for 144-pin 0.5mm-pitch LQFP.
  • Page 28: External Dimensions Of Converter Board (Flx-144Nse)

    (3) External Dimensions of Converter Board (FLX-144NSE) Figure 4.3 shows the external dimensions and a sample foot pattern of the pitch converter board FLX- 144NSE for 144-pin 0.4mm-pitch TQFP. Figure 4.3 External dimensions of FLX-144NSE (4) External Dimensions of Converter Board (FLX-120NSE) Figure 4.4 shows the external dimensions and a sample foot pattern of the pitch converter board FLX- 120NSE for 120-pin 0.4mm-pitch LQFP.
  • Page 29 Chapter 5. Troubleshooting This chapter describes how to troubleshoot when this product does not work properly. 5.1 When the Emulator Debugger Does Not Start Up Properly... 28 (1) When the LED Display of PC4701 is Abnormal ... 28 (2) Errors Occur When the Emulator Debugger Starts Up (When the target system is connected) ...
  • Page 30: Chapter 5. Troubleshooting

    Chapter 5. Troubleshooting When this product does not work properly, check the following. 5.1 When the Emulator Debugger Does Not Start Up Properly (1) When the LED Display of PC4701 is Abnormal Table 5.1 LED's abnormal display and its checkpoints Error LEDs do not light up.
  • Page 31: (When The Target System Is Connected)

    (2) Errors Occur When the Emulator Debugger Starts Up (When the target system is connected) Table 5.2 Checkpoints of errors when starting up the emulator debugger (target is connected) Error Communication ERROR Data is not sent to the target Target system is not constructed properly The version of M3T-PD30 and the firmware on the target system are not same Target MCU is reset state...
  • Page 32: (When The Target System Is Not Connected)

    (3) Errors Occur When the Emulator Debugger Starts Up Table 5.3 Checkpoints of errors when starting up the emulator debugger (target is not connected) Communication ERROR Data is not sent to the target Target system is not constructed properly The version of M3T-PD30 and the firmware on the target are not same Target is "HOLD"...
  • Page 33: Chapter 6. Maintenance And Warranty

    Chapter 6. Maintenance and Warranty This chapter describes how to maintenance, repair provisions and how to request for repair. 6.1 Maintenance ... 32 6.2 Warranty ... 32 6.3 Repair Provisions... 32 6.4 How to Request for Repair ... 33 ( 31 / 36 )
  • Page 34: Maintenance

    Chapter 6. Maintenance and Guarantee 6.1 Maintenance If dust or dirt collects on any equipment of your emulation system, wipe it off with a dry soft cloth. Do not use thinner or other solvents because these chemicals can cause the equipment's surface coating to separate.
  • Page 35: How To Request For Repair

    After checking the contents of fault, the distributor should please send the faulty product along with the Repair Request Sheet to Renesas Solutions Corp. When the faulty product is repaired, it will be returned to the customer at the earliest convenience.
  • Page 36 MEMO ( 34 / 36 )
  • Page 37 M30220T-PRB User's Manual Rev.1.00 September 1, 2003 REJ10J0281-0100Z COPYRIGHT ©2003 RENESAS TECHNOLOGY CORPORATION AND RENESAS SOLUTIONS CORPORATION ALL RIGHTS RESERVED...
  • Page 38 M30220T-PRB User’s Manual 1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 Japan REJ10J0281-0100Z...

Table of Contents