RS-232 Port

The NetPA U 2002 SB has a serial port that can be connected to a host device such as a
computer running either the DataViewer or HyperTerminal utilities. The port makes serial
control of the NetPA Ultra Series possible.
TheNetPA U 2002 SB amplifier uses the following baud rate and protocols:
38400 baud
NOTES:
The rear panel configuration port requires 38400 baud communication. This
speed is higher than most other Extron products. The NetPA Ultra Series control
software automatically sets the connection for the appropriate speed. When
using DataViewer or similar application, make sure the host PC or control system
is set for 38400 baud.
See
the RS-232 port.

AT Port

The NetPA U 2002 SB amplifier can be connected to a Dante network. SIS Commands can
be sent to Dante audio interface devices through a DMP Plus device. To learn how to do
this, visit
www.extron.com
matrix processors, such as the DMP 128 Plus.
The NetPA Ultra Series amplifier Dante port defaults are as follows:
DHCP: ON
The Ethernet cable can be terminated as a straight-through cable or a crossover cable and
must be properly terminated for your application.
Crossover cable — Direct connection between the computer and the NetPA Ultra
Series amplifier.
Straight-through (Patch) cable — Connection of the NetPA Ultra Series amplifier to
an Ethernet LAN.
Pins:
12345678
Insert Twisted
Pair Wires
RJ-45
Connector
Figure 93.
1 stop bit
Rear Panel Features
on page 17 for additional details on connecting to
and read any of the user guides from the DMP Plus series of
Crossover Cable
(for direct connection to a PC)
End 1
End 2
Pin
Wire Color
Pin
Wire Color
1
white-orange
1
white-green
2
orange
2
green
3
white-green
3
white-orange
4
blue
4
blue
5
white-blue
5
white-blue
6
green
6
orange
7
white-brown
7
white-brown
8
brown
8
brown
T568A
T568B
A cable that is wired as TIA/EIA T568A at one
end and T568B at the other (Tx and Rx pairs
reversed) is a "crossover" cable.
RJ-45 Ethernet Connector Pin Assignments
NetPA U 2002 SB User Guide • Remote Control and Communication
8 data bits
No parity
Straight-through Cable
(for connection to a switch, hub, or router)
End 1
Pin
Wire Color
Pin
1
white-orange
1
2
orange
2
3
white-green
3
4
blue
4
5
white-blue
5
6
green
6
7
white-brown
7
8
brown
8
T568B
A cable wired the same at both ends is called
a "straight-through" cable because no pin/pair
assignments are swapped.
End 2
Wire Color
white-orange
orange
white-green
blue
white-blue
green
white-brown
brown
T568B
86