Operating Guide | VACON® NXS/NXP Air-cooled
I
I
H*150%
I
H
1 min
Illustration 81:
High Overload
For more information, refer to the standard IEC61800-2.
12.7.2 Power Ratings for Mains Voltage 208–240 V
Table 51: Power Ratings in Mains 208–240 V, 50 Hz, 3~
Enclo‐
Drive
Input
sure
type
current
size
I
in
FR4
0003
3.7
0004
4.8
0007
6.6
0008
7.8
0011
11
0012
12.5
FR5
0017
17.5
0025
25
0031
31
FR6
0048
48
0061
61
FR7
0075
75
0088
88
0114
114
182 | Danfoss A/S © 2020.02
9 min
Low load‐
Low load‐
ability: I
ability:
L
10%
(1)
(2)
[A]
overload
I [A]
3.7
4.1
4.8
5.3
6.6
7.3
7.8
8.6
11.0
12.1
12.5
13.8
17.5
19.3
25
27.5
31
34.1
48
52.8
61.0
67.1
75.0
83.0
88.0
97.0
114.0
125.0
I
H*150%
t
High
High
loadabili‐
loadabili‐
ty: 50%
ty: I
[A]
H
overload
(2)
I [A]
2.4
3.6
3.7
5.6
4.8
7.2
6.6
9.9
7.8
11.7
11.0
16.5
12.5
18.8
17.5
26.3
25.0
37.5
31.0
46.5
48.0
72.0
61.0
92.0
75.0
113.0
88.0
132.0
Specifications
Loadabili‐
Motor
ty: Max I
shaft
S
(3)
power
:
2 s
10% over‐
load 40°C
[kW]
4.8
0.55
7.4
0.75
9.6
1.1
13.2
1.5
15.6
2.2
22.0
3.0
25.0
4.0
35.0
5.5
50.0
7.5
62.0
11.0
96.0
15.0
122.0
22.0
150.0
22.0
176.0
30.0
AQ275638903263en-000301 / DPD00910
Motor
shaft
(3)
power
:
50% over‐
load 50°C
[kW]
0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
22.0
22.0