2.2.4 Contact I/O

Contact I/O are sequence I/O signals used to control Servopack operation. Connect these
signal terminals as necessary.
Connecting Contact Input Signals
Connect contact input signal terminal connections as follows:
I/O power
supply
+24V
Host controller
0V
Note
Provide an external I/O power supply separately.
There are no power terminals to which the Servopack outputs signals externally.
External Power Supply: 24 1 VDC
50 mA or more
Yaskawa recommends that this external power supply be the same type as for the output cir-
cuit.
→ Input IN1 CN1-1
→ Input IN2 CN1-2
The function of input signal IN1 differs according to the setting of parameter Cn-2A.
The function of input signal IN2 differs according to the setting of parameter Cn-2B.
/CL
IN1,IN2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
2.2Setting Parameters According to Host Controller
Servopack
Photocoupler
4.7 KΩ
+24VIN
CN1-9
5 mA
IN1
CN1-1
CN1-2
IN2
Input
Signal
Selection 1
Input
Signal
Selection 2
Servopack
/S-ON
/P-CON
/ALMRST
/CL
— 2-21 —