Query The Serial Number; Setting The Rotary Direction Of The Jog Dial Knob; Control Lock; Identify The Device - Lightware MMX8x4-HT Series User Manual

Multiport matrix switcher
Hide thumbs Also See for MMX8x4-HT Series:
Table of Contents

Advertisement

 
8. LW3 Programmers' Reference
8.3.4. Query the Serial Number
Command and Response
Ý GET•/.SerialNumber
pr•/.SerialNumber=<serial_nr>
Ü
Example
Ý GET /.SerialNumber
Ü pr /.SerialNumber=00005484
8.3.5. Setting the Rotary Direction of the Jog Dial Knob
Command and Response
SET•/MANAGEMENT/UI.RotaryDirection=<direction>
Ý
pw•/MANAGEMENT/UI.RotaryDirection=<direction>
Ü
Parameters
<direction>
0: The rotary direction of down is clockwise.
1: The rotary direction of down is counter clockwise.
Example
Ý SET /MANAGEMENT/UI.RotaryDirection=0
Ü pw /MANAGEMENT/UI.RotaryDirection=0
8.3.6. Control Lock
Enable/disable the operation of the jog dial control knob.
Command and Response
SET•/MANAGEMENT/UI.ControlLock=<control_state>
Ý
pw•/MANAGEMENT/UI.ControlLock=<control_state>
Ü
Parameters
<control_state>
0: Unlocked - The jog dial knob (and the buttons) are unlocked.
1: Locked - The jog dial knob (and the buttons) are locked. In MMX8x8-HDMI-4K-A model,
locked status can be changed with LW3 protocol command or by pressing Control Lock
button for three seconds.
2: Force locked - The jog dial knob (and the buttons) are locked. This status can be changed
only with LW3 protocol command.
Example
Ý SET /MANAGEMENT/UI.ControlLock=1
Ü pw /MANAGEMENT/UI.ControlLock=1
MMX8x4-HT series – User's Manual
#controllock
Applied firmware package: v1.2.2b5 | LDC software: v2.2.1
8.3.7. Identify the Device
Calling the method results Device identified! message on the LCD screen. The feature helps to identify the
device itself in the rack shelf.
Command and Response
Ý CALL•/MANAGEMENT/UI:identifyMe()
Ü mO•/MANAGEMENT/UI:identifyMe
Example
Ý CALL /MANAGEMENT/UI:identifyMe()
Ü mO /MANAGEMENT/UI:identifyMe
8.3.8. Resetting the Matrix
The matrix can be restarted – the current connections (LAN, RS-232) will be terminated.
Command and Response
#reset
Ý CALL•/SYS:reset()
Ü mO•/SYS:reset=
Example
Ý CALL /SYS:reset()
Ü mO /SYS:reset=
8.3.9. Restore the Factory Default Settings
Command and
Response #factorydefault
Ý CALL•/SYS:factoryDefaults()
Ü mO•/SYS:factoryDefaults=
Example
Ý CALL /SYS:factoryDefaults()
Ü mO /SYS:factoryDefaults=
The device is restarted, current connections are terminated, and the default settings are restored.
See the complete list in
Factory Default Settings
section.
99