Test Pattern Generator - No Sync Screen; Audio Tab - Lightware MMX8x4-HT Series User Manual

Multiport matrix switcher
Hide thumbs Also See for MMX8x4-HT Series:
Table of Contents

Advertisement

 
5. Software Control – Lightware Device Controller
6.6.3. Test Pattern Generator - No Sync Screen
The output ports can send a special image towards the sink devices for testing purposes.
The setting is available on output ports with the following parameters:
Mode
On: the test pattern is always sent to the output port.
Off: the test pattern generator is off.
No signal: the test pattern generator is switched on if no video signal is switched to the given output
port.
Clock source
480p / 576p / Original video signal: the clock frequency of the test pattern.
Pattern
Red / Green / Blue / Black / White / Ramp / Chess / Bar / Cycle. Cycle setting means all the patterns
are changed sequentially approx. in every 2 seconds.
ATTENTION! The Mode can be set individually on each port, but the Clock source and Pattern settings are
the same on O1-O3 and O2-O4 output ports.
#nosyncscreen #testpattern
Test patterns
Applied firmware package: v1.2.2b5 | LDC software: v2.2.1
MMX8x4-HT series – User's Manual
6.7. Audio Tab
MMX8x4-HT400MC and MMX8x4-HT420M model
This tab is for overview of the input and output audio settings. See more details about the audio inputs and
outputs in
Audio Interface
section.
Audio tab in Crosspoint menu
63