Query The Ir Command Injection Port Number; Ir Port Messaging; Sending Pronto Hex Codes In Little-Endian Format Via Ir Port; Sending Pronto Hex Codes In Big-Endian Format Via Ir Port - Lightware MMX8x4-HT Series User Manual

Multiport matrix switcher
Hide thumbs Also See for MMX8x4-HT Series:
Table of Contents

Advertisement

 
8. LW3 Programmers' Reference
8.11.2. Query the IR Command Injection Port Number
Command and Response
Ý GET•/MEDIA/IR/<ir_port>.CommandInjectionPort
Ü pw•/MEDIA/IR/<ir_port>.CommandInjectionPort
Example
Ý GET /MEDIA/IR/D1.CommandInjectionPort
Ü pw /MEDIA/IR/D1.CommandInjectionPort
8.12. IR Port Messaging
8.12.1. Sending Pronto Hex Codes in Little-endian Format via IR Port
Command and
Response #message
Ý CALL /MEDIA/IR/<ir_port>:sendProntoHex(<hex_code>)
Ü mO /MEDIA/IR/<ir_port>:sendProntoHex
Parameters
Parameter
Identifier
description
<ir_port>
IR port number
<hex_code>
Pronto hex
format code
*The number of the ports depends on the model type. The exact port numbering is listed in
section.
INFO: This command can send exactly one pronto hex message.The header of the IR code contains the
length of the whole code in hexa format. If the code is deficient or duplicated, it causes syntax error.
For more details about the pronto hex codes see
Example
Ý CALL /MEDIA/IR/D3:sendProntoHex(00006D0025000300A900A80015003F00150 03F0
015003F0015001500150015001500150015001500150 0150015003F0015003F001500
3F00150015001500150 015001 500150015001500150015003F0015003F0015003F00150015001500
150015001500150015001500150015001500150015001500150015003F0015003F0015003F0015003
F0015003F0015000207A900A8001500150015006E0E)
Ü mO /MEDIA/IR/D3:sendProntoHex
Parameter values
D1-D4*
Accepts maximum 765
character-long code in
hexadecimal format (0-9; A-F;
a-f) without space character
in little-endian system.
Getting IR codes
section.
Applied firmware package: v1.2.2b5 | LDC software: v2.2.1
MMX8x4-HT series – User's Manual
8.12.2. Sending Pronto Hex Codes in Big-endian Format via IR Port
For more details about the pronto hex codes see
Command and Response
Ý CALL /MEDIA/IR/<ir_port>:sendProntoHexBigEndian(<hex_code>)
Ü mO /MEDIA/IR/<ir_port>:sendProntoHexBigEndian
Parameters
Identifier
<ir_port>
<hex_code>
*The number of the ports depends on the model type. The exact port numbering is listed in
section.
INFO: This command can send exactly one pronto hex message.The header of the IR code contains the
length of the whole code in hexa format. If the code is deficient or duplicated, it causes syntax error.
For more details about the pronto hex codes see
Example
Ý CALL /MEDIA/IR/D1:sendProntoHexBigEndian(0000006d0025000300a900a80015 003f0015003f0015
003f00150015001500150015001500150015001500150015003f0015003f0015003f001500150015001
Port Numbering
50015001500150015001500150015003f0015003f0015 003f001500150015001500150015001500150
01500150015001 500150015001500150015003f0015003f0015003f0015003f0015 003f0015070200a
900a80015001500150e6e)
Ü mO /MEDIA/IR/D1:sendProntoHexBigEndian
Getting IR codes
section.
Parameter
Parameter values
description
IR port number
D1-D4*
Pronto hex format
Accepts maximum 765
code
character-long code in
hexadecimal format (0-9;
A-F; a-f) without space
character in big-endian
system.
Getting IR codes
section.
122
Port Numbering

Advertisement

Table of Contents
loading

Table of Contents