8. LW3 Programmers' Reference
8.2.9. Notifications about the Changes of the Properties
When the value of a property is changed and the user is subscribed to the node, which the property belongs
to, an asynchronous notification is generated. This is notification is called as the 'change message'. The
format of such a message is very similar to the response for the GET command:
Ü CHG /EDID.EdidStatus=F48:E1
A Short Example of How to Use the Subscription
There are two independent users controlling the device through two independent connections (Connection #1
and Connection #2). The events in the rows occur after each other.
Ý OPEN /MEDIA/VIDEO/QUALITY
Ü o- /MEDIA/VIDEO/QUALITY
Ý GET /MEDIA/VIDEO/Quality.QualityMode
Ü pm /MEDIA/VIDEO/QUALITY.QualityMode=graphic
Ý GET /MEDIA/VIDEO/Quality.QualityMode
Ü pm /MEDIA/VIDEO/QUALITY.QualityMode=graphic
Ý SET /MEDIA/VIDEO/Quality.QualityMode=video
Ü pw /MEDIA/VIDEO/QUALITY.QualityMode=video
Ü CHG /MEDIA/VIDEO/QUALITY.QualityMode=video
Explanation: The first user (Connection #1) set a subscription to a node. Later the other user (Connection #2)
made a change, and thanks for the subscription, the first user got a notification about the change.
8.2.10. Legend for the Control Commands
Format
<in>
Input port number
<out>
Output port number
<port>
Input or output port number
<loc>
Location number
Variable, which is defined and described in the
<parameter>
command
Batched parameters: the underline means that
<expression>
more expressions or parameters can be placed by
using a semicolon, e.g. I2;I4;I5 or F27:E1;F47:E2
Sent command
Ý
Received response
Ü
Space character
}
Connection #1
}
Connection #2
Connection #1
Description
MMX8x4-HT series – User's Manual
8.3. System Commands
8.3.1. Query the Product Name
The name of the product is a read-only parameter and cannot be modified.
Command and Response
Ý GET•/.ProductName
pr•/.ProductName=<product_name>
Ü
Example
Ý GET /.ProductName
Ü pr /.ProductName=MMX8x4-HT420M
8.3.2. Query the Device Label
Command and Response
SET•/MANAGEMENT/UID/DeviceLabel=<custom_name>
Ý
pw•/MANAGEMENT/UID/DeviceLabel=<custom_name>
Ü
Parameters
<custom_name>
names will be truncated.
Example
Ý SET /MANAGEMENT/UID.DeviceLabel=MMX_Control_room
Ü pw /MANAGEMENT/UID.DeviceLabel=MMX_Control_room
8.3.3. Set the Device Label
ATTENTION! The device label can be changed to a custom text which is displayed in many windows of
the LDC. This writable parameter is not the same as the ProductName parameter.
Command and Response
SET•/MANAGEMENT/UID/DeviceLabel=<custom_name>
Ý
pw•/MANAGEMENT/UID/DeviceLabel=<custom_name>
Ü
Parameters
<custom_name>
names will be truncated.
Example
Ý SET /MANAGEMENT/UID.DeviceLabel=MMX_Control_room
Ü pw /MANAGEMENT/UID.DeviceLabel=MMX_Control_room
Applied firmware package: v1.2.2b5 | LDC software: v2.2.1
The Device Label can be 39 character long and ASCII characters are allowed. Longer
#devicelabel
The Device Label can be 39 character long and ASCII characters are allowed. Longer