9. LW3 Programmers' Reference
9.3.10. Notifications about the Changes of the Properties
When the value of a property is changed and the user is subscribed to the node, which the property belongs
to, an asynchronous notification is generated. This is notification is called as the 'change message'. The
format of such a message is very similar to the response for the GET command:
 CHG /EDID.EdidStatus=F48:E1
A Short Example of How to Use the Subscription
There are two independent users controlling the device through two independent connections (Connection #1
and Connection #2). The events in the rows occur after each other.
 OPEN /MEDIA/AUDIO/O3
 o- /MEDIA/AUDIO/O3
 GET /MEDIA/AUDIO/O3.VolumePercent
 pw /MEDIA/AUDIO/O3.VolumePercent=100.00
 GET /MEDIA/AUDIO/O3.VolumePercent
 pw /MEDIA/AUDIO/O3.VolumePercent=100.00
 SET /MEDIA/AUDIO/O3.VolumePercent=50.00
 pw /MEDIA/AUDIO/O3.VolumePercent=50.00
 CHG /MEDIA/AUDIO/O3.VolumePercent=50.00
The first user (Connection #1) set a subscription to a node. Later the other user (Connection #2) made a change,
and thanks for the subscription, the first user got a notification about the change.
9.3.11. Legend for the Control Commands
Format
<in>
Input port number
<out>
Output port number
<port>
Input or output port number
<loc>
Location number
<parameter>
Variable, which is defined and described in the command
Batched parameters: the underline means that more expressions or parameters can
<expression>
be placed by using a semicolon, e.g. I2;I4;I5 or F27:E1;F47:E2
Sent command
Ý
Received response
Ü
·
Space character
}
Connection #1
}
Connection #2
Connection #1
Description
Applied firmware package: v1.7.0 | LDC software: v2.5.1b5
MX2-HDMI20 series – User's Manual
9.4. System Commands
9.4.1. Querying the Product Name
The name of the product is a read-only parameter and cannot be modified.
Command and Response
Ý GET·/.ProductName
pr·/.ProductName=<Product_name>
Ü
Parameters
The
<Product_name>
is the type of the device: read-only parameter and cannot be modified.
Example
Ý GET /.ProductName
Ü pr /.ProductName=MX2-24x24-DH-12DPi-R
9.4.2. Setting the Device Label
The device label can be changed to a custom text which is displayed in many windows of the LDC.
ATTENTION! This writable parameter is not the same as the ProductName parameter.
Command and Response
#label #devicelabel
SET·/MANAGEMENT/UID/DeviceLabel=<Custom_name>
Ý
pw·/MANAGEMENT/UID/DeviceLabel=<Custom_name>
Ü
Parameters
The
<Custom_name>
may consist of ASCII characters and can be 32 characters length. Longer names are
truncated.
Example
Ý SET /MANAGEMENT/UID.DeviceLabel=MX2_Control_room
Ü pw /MANAGEMENT/UID.DeviceLabel=MX2_Control_room
9.4.3. Querying the Serial Number
Command and Response
Ý GET·/.SerialNumber
pr·/.SerialNumber=<serial_nr>
Ü
Example
Ý GET /.SerialNumber
Ü pr /.SerialNumber=87654321