3-ph. 480 V AC, 4Q units
6RA8013-6FV62
6RA8031-6FV62
6RA8082-6FV62
Table 4- 30
Technical data for 3-ph. 480 V AC, 4Q units
Common data
Rated
armature supply voltage 1)
Rated
field supply voltage 1)
Electronics power supply, rated supply
voltage
Rated DC voltage 1)
Rated
field DC voltage 1)
Rated frequency
Overload possibility 6)
Closed-loop control constancy
Degree of protection
Protection class
Table 4- 31
Technical data for 3-ph. 480 V AC, 15 A to 90 A, 4Q units
Order number 6RA80 ..
Rated DC current
Rated armature input current 2)
Rated power
Power loss at rated DC current
(approx.)
Rated field DC current
Type of cooling
Dimensions (HxWxD)
Weight (approx.)
SINAMICS DCM DC Converter
Operating Instructions, 1.2012, C98130-A7066-A1-05-7619
6RA8018-6FV62
6RA8075-6FV62
6RA8085-6FV62
V
3-ph. 480 V AC (+10 % / -20 %)
V
2-ph. 480 V AC (+10 % / – 20 %)
V
2-ph. 380 (– 25 %) to 480 V AC (+10 %); In = 1 A or
1-ph. 190 (– 25 %) to 240 V AC (+10 %); In = 2 A
(– 35 % for 1 min.)
With option L05: 18 to 30 V DC; In = 5 A
V
500
V
390
Hz
45 to 65 10)
Max. 1.8x rated DC current
Δn = 0.006% of rated motor speed during operation with incremental
encoder and digital setpoint
Δn = 0.1% of rated motor speed during operation with analog tachometer
or analog setpoint 5)
IP00 acc. to DIN EN 60529
Class I (with protective conductor system) and class III (PELV) to EN
61800-5-1
..13-6FV62
A
15
A
12.5
kW
6.3
W
131
A
3
Self-ventilated
mm
385x268x221
kg
11
6RA8025-6FV62
6RA8078-6FV62
6RA8087-6FV62
..18-6FV62
..25-6FV62
30
24.9
49.8
15
190
299
5
Self-ventilated
Self-ventilated
385x268x221
385x268x252
11
Technical data
4.3 Unit data
6RA8028-6FV62
6RA8091-6FV62
..28-6FV62
60
90
74.7
30
45
343
10
10
Self-ventilated
385x268x252
11
14
57