Replacing fans in 400 to 850 A units
Remove the front cover of the SINAMICS DC MASTER.
Disconnect the fan-sensor connector
Disconnect the connector for the fan's power supply
Release the screws
Pull the slide-in fan unit out towards you.
Insert a new fan module and screw it in place (tightening torque 1.5 Nm), reconnect the connectors, and replace the
front cover.
Figure 11-5
Replacing fans in 400 - 850 A units
SINAMICS DCM DC Converter
Operating Instructions, 1.2012, C98130-A7066-A1-05-7619
.
(tool: Torx T20 screwdriver)
.