Additional system components
7.3 Terminal Module TM15
6SL3055-0AA00-3FAx
Voltage drop in ON state
Leakage current in OFF state
Voltage drop, output
(I/O power supply to the output)
Max. total current of outputs (per group)
up to 60 °C
up to 50 °C
up to 40 °C
IEC enclosure specification
Protective conductor connection
Response time
Weight
Approvals
204
Unit
V
DC
μA
V
DC
A
DC
A
DC
A
DC
IP20 protection
On enclosure with M4/1.8 Nm screw
The response time for the digital inputs/outputs (TM15 DI/DO)
consists of the following elements:
Response time on the component itself
(approx. 1/2 DRIVE-CLiQ clock cycle).
Transmission time via the DRIVE-CLiQ connection
(approx. 1 DRIVE-CLiQ clock cycle).
Evaluation on the Control Unit (see function diagram)
For additional information:
SINAMICS DCM List Manual, Chapter "Function block diagrams"
kg
UL und cULus
http://www.ul.com
File: E164110, Vol. 2, Sec. 9
Operating Instructions, 1.2012, C98130-A7066-A1-05-7619
Value
0.75 (max.) for maximum load in all
circuits
Max. 10 per channel
0,5
2
3
4
0,86