Operation
9.1 Basic information
Copying parameter data sets from the Memory Card to non-volatile memory
There are two ways of copying parameter data sets from the Memory Card to non-volatile
memory:
● The system is powered down
● The system is switched on
Note
The parameter data set in the ROM is overwritten during system start-up. If a Memory Card
with a parameter data set is inserted when the system is switched on, the parameter data set
with the index 0 in the ROM will be overwritten by the new one with the index 0 on the
Memory Card.
296
– Insert a Memory Card containing a parameter data set with the index 0 into the CUD.
– Switch on the system. The new parameter data set will be copied to the ROM
automatically. The parameter data set with the index 0 which was previously in the
ROM will be overwritten.
– The system will then boot with the new parameter data set.
The user starts data transmission from the Memory Card to the ROM with parameters
p0802, p0803 and p0804:
– p0804 = 1
– p0802 = (0...100) as source (from the Memory Card) and p0803 = (0/10/11/12) as
target to the ROM.