Parameterizing A Motor Holding Brake - Siemens SINAMICS G110D Operating Instructions Manual

Hide thumbs Also See for SINAMICS G110D:
Table of Contents

Advertisement

Parameterizing the dynamic braking
Table 6- 39
Parameter
P0003 = 2
P1240 = 0
P1237
6.9.2.4

Parameterizing a motor holding brake

Motor holding brake applications
The motor holding brake prevents the motor turning when the inverter is switched-off. The
inverter has internal logic to control a motor holding brake.
The motor holding brake control inside the inverter is suitable for the following typical
applications:
● Pumps
● Fans
● Horizontal and vertical conveyors
SINAMICS G110D
Operating Instructions, 2009-05-15, A5E02385577A AB
Parameters to enable and set dynamic braking
Description
Extended access
Deactivate the V
controller
DCmax
Enable signal and ON period of dynamic braking
0: Dynamic braking is locked
1: 5% ON period**
2: 10% ON period
3: 20% ON period
4: 50% ON period
5: 100% ON period
The ON period set here is only effective if the braking resistor has reached its operating
temperature. When required, a cold braking resistor is switched-in independent of this
parameter
**) SIEMENS resistors are designed for 5% ON period
Functions
6.9 Technological functions
117

Hide quick links:

Advertisement

Table of Contents
loading