150 en | Event messages
Resolve: When the error is no longer present or when the device disconnects.
Recommended action:
Event: Mains power supply failure (charger function lost)
Group: Fault
Occurrence: Logs the failure of the mains supply
Originator: Device with the power supply.
Resolve: When the error is no longer present or when the device disconnects
Recommended action:
Extra information: The charger is suspended when this fault is active.
Event: Battery fault: Battery disconnected (charger function disabled)
Group: Fault
Occurrence: Logs the failure of the backup supply.
Originator: Device with the power supply
Resolve: When the error is no longer present or when the device disconnects.
Recommended action:
Extra information:
Event: ChargerSupplyTooLow
Group: Fault
Occurrence: To indicate the charger supply voltage is too low.
Originator: MPS
Resolve: When the error is no longer present or when the device disconnects.
Recommended action:
Extra information: The charger is suspended when this fault is active.
Event: BatteryOvervoltage
Group: Fault
Occurrence: Indicates if there is an overvoltage situation on the battery. The charger
converter is turned off.
Originator: MPS
Resolve: Recovery is not possible. Turn off the MPS.
Recommended action:
Extra information:
Event: BatteryUndervoltage
Group: Fault
Occurrence: Indicates if there is an under voltage situation when mains is absent, the sepics
are turned off when this fault occurs.
2020-09 | V1.20 | PRAESENSA 1.20
Check the MPS mains input power, lines and connections.
Check the configuration.