  • Page 1 Plena Voice Alarm System Software Manual Configuration Software...
  • Page 3: Table Of Contents

    Plena Voice Alarm System | Software Manual | Table of Contents en | 3 Table of Contents Table of Contents ................................3 1. Introduction ..................................7 Purpose .....................................7 Digital document ..................................7 Intended audience ..................................7 Related documentation ................................7 2. Getting started ................................9 Introduction ....................................9 System requirements ................................9...
  • Page 4 Plena Voice Alarm System | Software Manual | Table of Contents en | 4 4.3.2 New zone group ................................16 4.3.3 Delete zone groups ................................ 17 4.3.4 Rename zone groups ..............................17 5. Supervision .................................. 19 Overview ....................................19 Short circuit check ................................19 Network ....................................
  • Page 5 Plena Voice Alarm System | Software Manual | Table of Contents en | 5 7.2.5 Mic/line input ................................... 36 Router ..................................... 37 Call station ..................................... 37 7.4.1 Introduction ..................................37 7.4.2 Main ....................................37 7.4.3 Keypad ....................................38 8. Configuration file ..............................41 Overview ....................................
  • Page 6 Plena Voice Alarm System | Software Manual | Table of Contents en | 6 Bosch Security Systems | 2005-10 | 9922 141 10384 en...
  • Page 7: Introduction

    Plena Voice Alarm System | Software Manual | Introduction en | 7 Introduction 1. 1 Purpose The purpose of the Configuration Software Manual is to provide information that is required to install and use the Plena Voice Alarm System Configuration Software.
  • Page 8 Plena Voice Alarm System | Software Manual | Introduction en | 8 Intentionally left blank. Bosch Security Systems | 2005-10 | 9922 141 10384 en...
  • Page 9: Getting Started

    Installation figure 2.2: Set-up file Proceed as follows: 1 Put the Plena CD-ROM in the CD-ROM drive of the 3 Click Plena_VAS_SETUP_0101.EXE. A window PC. The CD-ROM starts automatically and a similar to the one in figure 2.3 appears.
  • Page 10: Connection

    Plena Voice Alarm System | Software Manual | Getting Started en | 10 Start 4 Click Open to open the set-up file of the configuration software. A window similar to the one Proceed as follows: in figure 2.4 appears. Follow the instructions that are 1 Go to the desktop of Windows (see figure 2.6 for an...
  • Page 11: Main Menu

    Plena Voice Alarm System | Software Manual | Getting Started en | 11 Main menu 2.6.4 Supervision The Supervision button opens the Supervision window 2.6.1 Overview (see chapter 5). Use this window to configure the The main menu (see figure 2.8) gives access to all supervision settings of the system.
  • Page 12 Plena Voice Alarm System | Software Manual | Getting Started en | 12 Intentionally left blank. Bosch Security Systems | 2005-10 | 9922 141 10384 en...
  • Page 13: System

    Plena Voice Alarm System | Software Manual | System en | 13 System The buttons at the bottom of the System window are used to: • Save changes (Save) 3. 1 Overview • Cancel changes (Cancel) Use the System window (see figure 3.1) to enter •...
  • Page 14: Remote Control Panels

    Plena Voice Alarm System | Software Manual | System en | 14 Remote control panels Use the Number of RC panels drop-down list to select the number of remote controls (LBB1995/00, LBB1996/ 00 and LBB1997/00) in the system. Control panel extensions...
  • Page 15: Zones

    Plena Voice Alarm System | Software Manual | Zones en | 15 Zones Zones 4.2.1 Introduction 4. 1 Overview All zones have a default name: Use the Zones window (see figure 4.1) to rename zones • Zones that are connected to the voice alarm and manage zone groups.
  • Page 16: New Zone Group

    Plena Voice Alarm System | Software Manual | Zones en | 16 4.3.2 New zone group 3 Click the Add zones button to add zones to the zone Proceed as follows: group. A window similar to the one in figure 4.4 1 Click the New button.
  • Page 17: Delete Zone Groups

    Plena Voice Alarm System | Software Manual | Zones en | 17 4.3.3 Delete zone groups 3 Enter the new name of the zone group in the text Proceed as follows: box (e.g. Visitors’ wing) and push the OK button. The...
  • Page 18 Plena Voice Alarm System | Software Manual | Zones en | 18 Intentionally left blank. Bosch Security Systems | 2005-10 | 9922 141 10384 en...
  • Page 19: Supervision

    Plena Voice Alarm System | Software Manual | Supervision en | 19 Supervision Network Use the Network box to enable and disable supervision of the network. By default, this box contains a 5. 1 Overview checkmark, which means that supervision of the Use the Supervision window to configure the network is enabled.
  • Page 20: Line Supervision

    Plena Voice Alarm System | Software Manual | Supervision en | 20 5. 1 1 Line supervision 3 Enter the time at which the line supervision must be started or put a checkmark in the Immediately box if 5.11.1 General line supervision must be started automatically.
  • Page 21: Input Supervision

    Plena Voice Alarm System | Software Manual | Supervision en | 21 5. 1 2 Input supervision Use the Enable box in the Input Supervision block to enable and disable input supervision. By default, this box does not contain a checkmark, which means that input supervision is disabled.
  • Page 22 Plena Voice Alarm System | Software Manual | Supervision en | 22 Intentionally left blank. Bosch Security Systems | 2005-10 | 9922 141 10384 en...
  • Page 23: Messages

    Plena Voice Alarm System | Software Manual | Messages en | 23 Messages About messages 6.2.1 Wave files 6. 1 Overview All messages are based on one or more wave files. Use the Messages window (see figure 6.1) to manage These wave files must be selected from the PC.
  • Page 24: Select Wave Files

    Plena Voice Alarm System | Software Manual | Messages en | 24 Select wave files 6.3.1 Overview See figure 6.2 for an overview of the Select wave files window. figure 6.2: Select wave files The buttons at the bottom of the Select wave files window are used to: •...
  • Page 25: Add Wave Files

    Plena Voice Alarm System | Software Manual | Messages en | 25 Edit templates 6.3.2 Add wave files Proceed as follows: 6.4.1 Overview 1 Go to the first empty line in the list. Wave files can only be added to the bottom of the list.
  • Page 26: Create A Template

    Plena Voice Alarm System | Software Manual | Messages en | 26 6.4.2 Create a template Proceed as follows: 1 Open the Edit mergeable message window. 2 Select the number of the template from the Template drop-down list. For example, 2. An empty template Note The procedure below is the general procedure.
  • Page 27 Plena Voice Alarm System | Software Manual | Messages en | 27 4 Select alert chime from the Wave file drop-down list 6 Select floor from the Wave file drop-down list in in row 1 (see figure 6.7). row 3 (see figure 6.9).
  • Page 28: Edit Messages

    Plena Voice Alarm System | Software Manual | Messages en | 28 Edit messages 8 Select immediately from the Wave file drop-down list in row 5 (see figure 6.11). 6.5.1 Overview See figure 6.12 for an overview of the Edit messages window.
  • Page 29: Create A Message

    Plena Voice Alarm System | Software Manual | Messages en | 29 6.5.2 Create a message 3 Select None from the Template drop-down list to create a message that is not based on a template. 4 Select the first component of the template from the Wave file drop-down list in row 1.
  • Page 30: Create A Mergeable Message

    Plena Voice Alarm System | Software Manual | Messages en | 30 6.5.3 Create a mergeable message Proceed as follows: 1 Open the Edit messages window. 2 Click the New button. A window similar to the one in section figure 6.16 appears.
  • Page 31: Listen To Messages

    Plena Voice Alarm System | Software Manual | Messages en | 31 4 Select Floor evacuation from the Template drop- The Floor evacuation template can also be used to create down list to create a message that is based on the a evacuation message for floor 2.
  • Page 32: Delete Messages

    Plena Voice Alarm System | Software Manual | Messages en | 32 6.5.6 Delete messages Proceed as follows: 1 Select the message that must be deleted from the Name drop-down list. 2 Click the Delete button. 6.5.7 Rename messages Caution Not not change the name of a message after you have completed the action programming.
  • Page 33: Action Programming

    Plena Voice Alarm System | Software Manual | Action Programming en | 33 Action programming 7.2.2 Front panel See figure 7.2 for an overview of the Front panel tab. 7. 1 Overview Use the Action programming window (see figure 7.1) to program the actions of buttons, trigger inputs, etc.
  • Page 34: Emg Trigger

    Plena Voice Alarm System | Software Manual | Action Programming en | 34 7.2.3 EMG trigger 7.2.3.3 Induvidual fault settings 7.2.3. 1 Overview Proceed as follows for each fault input: See figure 7.3 for an overview of the EMG trigger tab.
  • Page 35 Plena Voice Alarm System | Software Manual | Action Programming en | 35 Closed Closed Open Open Close, Momentary Open, Toggle figure 7.4: Close, Momentary figure 7.7: Open, Toggle Closed Open Open, Momentary figure 7.5: Open, Momentary Closed Open Close, Toggle figure 7.6: Close, Toggle...
  • Page 36: Business Trigger

    Plena Voice Alarm System | Software Manual | Action Programming en | 36 7.2.4 Business trigger 7.2.4.3 General settings 7.2.4. 1 Overview Proceed as follows: See figure 7.8 for an overview of the Business trigger 1 Select Action to set the condition when a trigger is tab.
  • Page 37: Router

    Plena Voice Alarm System | Software Manual | Action Programming en | 37 Router Call station Use the tabs to select the items for which the actions are 7.4.1 Introduction programmed: • Emergency trigger inputs (EMG trigger) Use the tabs to select the items for which the actions are programmed: •...
  • Page 38: Keypad

    Plena Voice Alarm System | Software Manual | Action Programming en | 38 7.4.3 Keypad 4 Assign zones to the zone selection buttons of the call station with the Select zones drop-down lists (see See figure 7.12 for an overview of the Keypad tab.
  • Page 39 Plena Voice Alarm System | Software Manual | Action Programming en | 39 Bosch Security Systems | 2005-10 | 9922 141 10384 en...
  • Page 40 Plena Voice Alarm System | Software Manual | Action Programming en | 40 Bosch Security Systems | 2005-10 | 9922 141 10384 en...
  • Page 41: Configuration File

    Plena Voice Alarm System | Software Manual | Action Programming en | 41 Configuration file 8. 1 Overview The Save configuration file button saves the configuration to your PC. The configuration file is saved as a *.dat file and takes the name of the day that the file was originally saved as the name of the file.
  • Page 42 Plena Voice Alarm System | Software Manual | Action Programming en | 42 Bosch Security Systems | 2005-10 | 9922 141 10384 en...
  • Page 43: Modify Password

    Plena Voice Alarm System | Software Manual | Action Programming en | 43 Modify password 9. 1 Overview Passwords can be changed for both software and hardware. Passwords have these criteria: • Contain at least four numbers or letters. •...
  • Page 44 Plena Voice Alarm System | Software Manual | Action Programming en | 44 Bosch Security Systems | 2005-10 | 9922 141 10384 en...
  • Page 45: Upload And Download

    Plena Voice Alarm System | Software Manual | Action Programming en | 45 Upload and download 10. 1 Overview The configuration file has to be uploaded to a system for the configuration file to take effect. The upload can use two methods: •...
  • Page 46 Plena Voice Alarm System | Software Manual | Action Programming en | 46 Bosch Security Systems | 2005-10 | 9922 141 10384 en...