Panasonic HL-D3 Series User Manual page 290

High speed, multi-point laser displacement sensor
Table of Contents

Advertisement

Connectable Sensor
Head
Setting / Data Display
Power Indicator
HEAD Indicator
(A, B)
Alarm Indicator
Vibration Withstand
Mechanical Shock
Withstand
Ambient Temperature
Ambient Humidity
Enclosure Material
Weight
Unspecified measurement conditions (with sensor head) are subject to the followings.
Power supply: 24V DC, ambient temperature: 20
Control (MZBC), adjusting increment: Width 100 μm, unit detection time: 100 µs,
measurement center distance, average number: 64 times, sensing object: white diffusive
object (which is specified by us). All others are the initial settings.
*1 The value is applicable under the following conditions: Measurement mode: Multi-Zone
Beam Control, Number of sensor head connected: 1, Each measurement range:
maximum, Beam power control count: 0 (continuous), Judgment output: 1 and 2 output
*2 Under the following conditions, the value is applicable in case of getting displacement
figure profiles by data buffering. Measurement mode: Whole-Synchronized, Number of
sensor head connected: 2, Each measurement range: minimum, No OUT calculation.
*3 The value is applicable under the following conditions: Measurement mode:
Multi-Select Displacement Sensing (MSDS), Number of sensor head connected: 1, unit
receiving time: 40 µs, Number of laser intensity control: 0 (continuous), Number of
selected position: 2, Wide-cell: none, Judgment output: 1 and 2 output
* The sensor head of Ver.1.20 or earlier can not connect to a Ver.2.0x controller. The alarm
output of the head will turn On.
HL-D3SMI (bundled application software) or dedicated API
A green LED: it glows when power is supplied.
During continuous measurement: it glows when laser radiation is emitted and
it alternates between blinking twice and one-second pause when laser
radiation is stopped emitting.
During halt of measurement: it flickers every one second when laser
radiation is emitted and it alternates between blinking once and one-second
pause when laser radiation is stopped emitting.
No head Connection: OFF
It glows when in alarm state during measurement or when a sensor cable is
10 to 55 Hz frequency (1 min. cycle), 0.75 mm double amplitudes, applied in
X, Y, and Z direction for 30 minutes
2
196m/s
applied in X, Y, and Z directions 3 times each
Operation: 0 to +50 °C (With no dew condensation nor icing) Storage: -20 to
8-3
HL-D3C
Max. 2 units
Green LED
Red LED
disconnected.
+70°C
35 to 85% RH
Enclosure: Aluminum
About 300g
°C
, measurement mode: Multi-Zone Beam
Chapter 8 Specifications
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hl-d3cHl-d301bHl-d301c

Table of Contents