Panasonic HL-D3 Series User Manual page 249

High speed, multi-point laser displacement sensor
Table of Contents

Advertisement

Chapter 5 External communication control
20
FORMAT
The measurement value of OUT1-6 and the judgment value status is loaded
at once.
● Load Command
Request communication data
% E E # R M B E
Normal response communication data
% E E $ R M B
± 9 9 9
5
± 9 9 9
± 9 9 9
± 9 9 9
The measurement value is a 1-digit symbol + 3-digit integral part (no zero
suppression) + decimal point + 4-digit decimal part.
1H, 2H, -, and 5H shows the H judgment output of each OUT.
1G, 2G, -, and 5G shows the G judgment output of each OUT.
1L, 2L, -, and 5L shows the L judgment output of each OUT.
1H 1G 1L 1A - 5H 5G 5L 5A and (6) is a single digit each and shows the
ON/OFF.
0: OFF
1: ON
All output load
Header
Command
Command
Header
9 9 9 0 2H 2G 2L 2A
.
OUT2:Measurement value and judgment result
9 9 9 0 3H 3G
.
.
9 9 9 0
OUT4:Measurement value and judgment result
.
9 9
OUT5:Measurement value and
judgment result
CR
BCC
Code
9 9 9 0 1H 1G 1L 1A
± 9 9 9
.
OUT1:Measurement value and judgment result
3L
3A
Command
4G
4L 4A
4H
5G 5L 5A
0 5H
9
5-30
CR
BCC
OUT6:Total judgment result