Chapter 4 Description of Functions
 Output mode
This changes the output of each output terminal (Hi, Go, Lo, alarm).
Normal open
Normal close
(at default)
 Output OFF delay
When each output terminal is ON, the time to hold ON status is set.
Select the appropriate item corresponding to input response of an external co n-
nection device (e.g. PLC).
No delay (default
4
value)
2ms / 10ms / 100ms
/ 200ms / 1s
Hold
The output OFF delay is not shown on the judgment result display of the
"Measurement value screen" in the HL-D3SMI. Use the buffering function to
check the data.
Settings
Usually sets the COM (-) to open (disconnected) and
closed (shorted) when the judgment results are ON.
Usually sets the COM (-) to closed (shorted) and open
(disconnected) when the judgment results are ON.
Settings
Output is updated every sampling cycle.
(Minimum 150 μs to 5 ms)
Once the output is ON, holds the output terminal
status during the selected time even when the judg-
ment result is OFF.
Once the output is ON, holds the status.It is can-
celled with reset input.
(For each hold measurement, reset of the hold meas-
urement is executed at the same time.)
Hi judgment value
Measurement
value
Lo judgment value
ON
Hi output
OFF
ON
GO output
OFF
ON
Lo output
OFF
Timing chart of output OFF delay
Description
Description
Delay time
4-100