Panasonic HL-D3 Series User Manual page 175

High speed, multi-point laser displacement sensor
Table of Contents

Advertisement

Chapter 4 Description of Functions
■Input terminal layout settings
Six inputs (ZS1/2, TM1/2, RS1/2) of the terminal block can be la id out arbi-
trarily in the following combinations.
Input target
OUT1
OUT2
OUT3
OUT-OUT calc. 1
OUT-OUT calc. 2
Shape judge
OUT1 to OUT3 (batch)
4
The terminal name notations on the controller and the I/O terminal blocks
are indicated in the initial state of function. When the terminal layout is
changed, note that the notations of the terminal names and functions
(signal type) will be different.
Type
Zero set
Timing
Reset
Arbitrary layout
Terminal input I1 - I6
"OUT1~OUT3 (batch)" inputs OUT1-3 collectively by 1 input.
Ex.: When "OUT1-OUT3 (batch)" - "Zeroset" is selected for "I1",
the zeroset of OUT1-3 can be controlled by 1 input I1.