15
FORMAT
It is the format for handling the value with two symbols.
● Load Command
Request communication data
% E E # R
Normal response communication data
% E E $ R
Header
±
5
Example
When the shift volume of OUT1 is loaded.
Request communication data
% E E # R S V 1
Normal response communication data
% E E $ R S V
For value setting 2
Header
Command
Command
9 9 9
.
9 9 9
Data2: 1-digit symbol + 3-digit integral part
(no zero suppress) + decimal point
+ 4-digit decimal part
0 0 1
.
0 0 0
Shift volume 2:+1.0000[mm]
(Minimum digit is fixed to 0.)
CR
BCC
Code
±
9 9 9
.
9 9 9
Data1: 1-digit symbol + 3-digit integral part
(no zero suppress) + decimal point
+ 4-digit decimal part
CR
0
BCC
CR
0 0 2
.
5 0 0
CR
0
5-24
0
0
Shift volume 1:+2.5000[mm]
(Minimum digit is fixed to 0.)